摘要
灌区用水计量设施率定是实现灌区取用水监控由水位/电量向水量转化的关键,为保证率定工作的正常开展和率定数据的真实可靠,在总结浙江省335处用水计量设施率定工作中遇到的困难的基础上,从率定技术路线,率定数据采集和保存,率定数据计算和分析等方面提出相对应的解决方案,以期为同类率定工作的开展提供经验借鉴。
The calibration of water metering facilities in irrigation districts is the key to realize the monitoring of water level/electricity to water volume in irrigation districts.In order to ensure the normal development of the calibration work and the reliability of the data,this paper summarizes the calibration of 335 water metering facilities in Zhejiang Province.On the basis of the difficulties encountered in the work,the corresponding solutions are proposed from the aspects of the calibrationtechnical route,the calibrationdata collection and preservation,and the calibrationdata calculation and analysis,in order to provide experience for the similar work.
作者
吴自成
吴凌霄
卢成
张亚东
胡荣祥
WU Zicheng;WU Lingxiao;LU Cheng;ZHANG Yadong;HU Rongxiang(Zhejiang Institute of Hydraulics and Estuary,Hangzhou 310020,China)
出处
《水利信息化》
2020年第2期38-41,共4页
Water Resources Informatization
关键词
用水计量
设施率定
灌区
问题
对策
浙江省
water metering
facility rate setting
irrigation area
problem
countermeasure
Zhejiang Province