重复短脉冲下相对湿度对变频电机绝缘局部放电及耐电晕寿命影响研究 被引量:6

Influence of Relative Humidity on Partial Discharge and Corona-resistant Lifetime Under Short Repetitive Impulsive Voltage for Inverter-fed Motor Insulation
下载PDF
导出
摘要 在上升时间为10 ns、电压幅值为3.5 kV、频率为5 kHz的重复单极性短脉冲下,实验研究了相对湿度分别为30%、50%、70%、90%时变频电机匝间绝缘的局部放电及耐电晕特性。结果表明:随着相对湿度的增加,试样的耐电晕寿命逐渐缩短,局部放电幅值先减小至某临界值后明显增大。这是由于随着相对湿度增加,电荷驻留效应减弱导致局部放电幅值减小,但当湿度超过某临界值后,微水聚集增强了局部电场,局部放电幅值增加。同时,微水的附着使试样的介电常数增加,从而使气隙间电场强度增大,这可能是其耐电晕寿命缩短的原因。 The partial discharge and corona-resistant features of the turn-to-turn insulation of inverter-fed motor at different relative humidity conditions(30%, 50%, 70%, 90%) were studied under unipolar repetitive short impulse voltage with 10 ns of rise time, 3.5 kV of voltage amplitude, and 5 k Hz of the frequency. The results show that with the increase of relative humidity, the corona-resistant lifetime decreases gradually, while the partial discharge amplitude decreases to a certain value and then increases significantly. This is because with the increase of relative humidity, the resident effect of charge reduces, leading to the decrease of partial discharge amplitude. However, when the humidity exceeds a certain critical value, the micro-water would accumulate and enhance the local electric field, resulting in the increase of partial discharge amplitude. At the same time, the attachment of micro-water increases the dielectric constant of sample, leading to the increase of electric field intensity in the air gap, which may be the reason for the decrease of its corona-resistant lifetime.
作者 李颖 王鹏 郑昌江 LI Ying;WANG Peng;ZHENG Changjiang(College o f Electrical Engineering,Sichuan University,Sichuan 610065,China)
出处 《绝缘材料》 CAS 北大核心 2020年第4期33-38,共6页 Insulating Materials
基金 国家自然科学基金资助项目(51407121、51977134)。
关键词 变频电机 绝缘系统 重复短脉冲 局部放电 耐电晕寿命 inverter-fed motor insulation system repetitive short impulsive voltage partial discharge corona-resistant lifetime
  • 相关文献

参考文献2

二级参考文献35

  • 1毛颖科,关志成,王黎明,毛苏春.污秽实验室泄漏电流测量系统的研制[J].高压电器,2007,43(2):94-96. 被引量:30
  • 2毛颖科.基于泄漏电流的电力系统外绝缘监测和评估方法[D].北京:清华大学,2008.
  • 3姜欣斌.绝缘子泄漏电流特性研究[D].北京:清华大学,2010.
  • 4Krystian Chrzan,Zbigniew Pohl. Hygroscopic properties of pol- lutants on HV insulators[J]. IEEE Transactions on Electrical Insulation, 1989, 24(1) : 107-112.
  • 5Gouda 0 E. Flashover of overhead HVTL insulators under des-err pollution conditions[C]//1990 IEEE Annual Report Confer- ence on Electrical Insulation and Dielectric Phenomena (CEIDP 1990): IEEE Confernece Publications. Pocono Manor, USA: IEEE, 1990: 605-611.
  • 6EI-Sulaiman A, Iqbal Qureshi M. Effect of contamination on the leakage current of inland desert insulators[J]. IEEE Trans- actions on Electrical Insulation, 1984,19 (4), 332-339.
  • 7Krystian Leonard Chrzan. Leakage current on naturally con- taminated porcelain and silicone insulators[J]. IEEE Transac- tions on Power Delivery,2010, 25 (2):904-910.
  • 8Kumagai S. Leakage current characterization for estimating the conditions of ceramic and polymeric insulating surfaces [J] IEEE Transactions on Dielectrics and Electrical Insulation, 2004,11(4) :681-690.
  • 9Li Jingyan, Sun Caixin, Sima Wenxia, et al. Contamination level prediction of insulators based on the characteristics of leakage current[J]. IEEE Transactions on Power Delivery, 2010, 25 (1) :417-424.
  • 10Karady G. The effect of fog parameters on the tesdng of artifi cially contaminated insulators in a fog chamber [J ]. IEEE Transactions on Power Apparatus and Systems, 1975, 91(1): 378 387.

共引文献26

同被引文献66

引证文献6

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部