泉州闽光3#高炉因热风炉系统故障,被迫无计划休风21h35min,休风期间采取有力的保温措施,通过优化复风方案,合理控制各项操作参数,复风16h后炉况快速恢复到正常生产水平,取得良好的效果。
Hot blast furnace system failure in Quanzhou Minguang No.3 blast furnace,forced unplanned wind break 21h35min,Take effective heat preservation measures during wind break,By optimizing the complex wind scheme,Control all operation parameters reasonably,After 16 hours of re air,the furnace condition quickly recovered to the normal production level,Good results have been achieved.
作者
杨进勇
Yang Jinyong(Fujian Quanzhou min Guang and steel Co.,Ltd.,Quanzhou 362411,Fujian)
出处
《福建冶金》
2020年第3期17-20,共4页
Fujian Metallurgy
关键词
高炉
无计划休风
快速恢复
blast furnace
no plan to rest
fast recovery