摘要 目的研究CT虚拟平扫对肺原发性淋巴组织增生性疾病的诊断价值。方法将本院体检的68例胸片检测疑似为肺原发性淋巴组织增生患者为研究对象,均采用CT常规平扫和双能量增强扫描。对比虚拟平扫和常规平扫的检测结果、阳性率和特异性。结果CT虚拟平扫对肺原发性淋巴组织增生性疾病诊断的灵敏度、准确度分别为92.86%、86.76%,略低于常规平扫检查的92.98%和91.23%差异无统计学意义(P>0.05);两者在疾病特异性和疾病类型诊断差异也无统计学意义(P>0.05)。结论CT虚拟平扫对肺原发性淋巴组织增生性疾病诊断准确性与常规平扫基本一致,具有较高的应用价值。 Objective To study the diagnostic value of CT virtual plain scan for primary pulmonary lymphoproliferative disease.Methods 68 cases of patients suspected as primary pulmonary lymphoproliferative disease by chest radiographs who had physical examination in our hospital were selected for the study.All patients were given CT plain and double energy enhanced scanning.The detection results,positive rate and specificity of virtual plain scan and conventional plain scan were compared.Results The sensitivity and accuracy of CT virtual plain scan with 92.86%and 86.76%were lower than those of conventional plain scan with 92.98%and 91.23%in the diagnosis of primary pulmonary lymphoproliferative disease(P>0.05).There were no significant differences in the disease specificity and disease types between the two methods(P>0.05).Conclusion The diagnostic accuracy of CT virtual plain scan for primary lymphoproliferative disease of lung is basically the same as that of conventional plain scan,and it has higher application value.
作者 牛一鸣 NIU Yi-ming(Department of Radiology,Panjin Liaohe Oilfield Gem Flower Hospital,Panjin 124010,Liaoning Province,China)
出处 《中国CT和MRI杂志》 2020年第5期120-121,125,共3页 Chinese Journal of CT and MRI
关键词 电子计算机断层扫描 虚拟平扫 肺原发性 淋巴组织增生 Computed Tomography Virtual Plain Scan Primary Pulmonary Lymphadenosis
  • 相关文献

参考文献10

二级参考文献103

  • 1王骏,赵国良,李苏建,周正良,张玥玥,陈新.胸部DR双能量减影与DR胸片及胸部CT吸收剂量对照研究[J].放射学实践,2011,26(1):90-93. 被引量:17
  • 2陈明华,钱明山,杨少平,蔡磊,王洪生.肺部CT检查低剂量与常规剂量的对照研究[J].实用中西医结合临床,2006,6(2):17-19. 被引量:5
  • 3陈国勤,顾莹莹,莫明聪,林云恩,杨通,刘慕嫦.肺内淋巴结误诊12例分析[J].中国热带医学,2007,7(7):1172-1173. 被引量:3
  • 4孙忠实.X线含碘对比剂合理使用[J].放射学实践,2008,23(1):93-94. 被引量:8
  • 5Avrin D E, Macovski A, ZatzL E. Clinical application of compton and photo-electric reconstruction in computed tomography : prelim- inary results[J]. Invest Radiol,1978,13(3) :217-222.
  • 6Lin X Z,Miao F,Li J Y,et al. High-definition CT Gemstone spec tral imaging of the brain:initial results of selecting optimal rnono chromatic image for beam-hardening artifacts and image noise re duction[J]. J Comput Assist Tomogr,2011,35(2):294-297.
  • 7Lv P,Lin X Z,Li J,et al. Differentiation of small hepatic heman- gioma form small hepatocellular carcinoma: recently introduced spectral CT method[J]. Radiology, 2011,259 (3) : 720- 729.
  • 8I.i X,Wang X,Yu Y, et al. Detection of uric acid depositing in to phaceous gout using a new dual energy spectral CT technology [J].J XraySciTechnol,2014,22(4):541- 549.
  • 9Deng K,Zhang C O,Li W,et al. Preliminary application of high- definition CT gemstone spectral imaging in hand and foot tendons [J].Korean J Radiol,2012,13(6):743 -751.
  • 10Francone M, Napoli A, Carbone I, et al. Noninvasive imaging of the coronary arteries using a 64-row multidetector CT scanner: initial clinical experience and radiation dose concerns [ J]. Radilo Med, 2007,112:31-46.