基于CODCr的K2 Cr2O7滴定法和HACH(哈希公司)DR6000,结合design-expert拟合分析,得到CODCr精确测量的最佳方案:消解液加入量为3 mL,K2 Cr2O7与H2 SO4-Ag2 SO4的加入比为1:5(V/V),K2Cr2O7溶液0.046 g/mL、H2SO4-Ag2SO4溶液3 g/L、HgSO40.038 g/支,恒温120℃消解2 h。同时,基于拟定的最佳方案分析了营养盐类对CODCr测定结果的影响,发现氨氮和亚硝态氮对测定结果有明显影响,而磷酸盐和偏磷酸盐对测定结果的影响较小。
Based on K2Cr2O7 titration of CODCr and HACH DR6000,combined with design-expert software fitting,the optimal method of measuring CODCr was obtained which showed that the amount of digestion solution was 3 mL,the ratio of K2Cr2O7 to H2SO4-Ag2SO4 was 1∶5(V/V),K2Cr2O7 solution was 0.046 g/mL,H2SO4-Ag2SO4 solution was 3 g/L,HgSO4 was 0.038 g/branch,and the digestion temperature was 120℃ for 2 h.At the same time,the effects of the nutrient salts on the determination of CODCr in optimal method were verified by experiments.The results showed that ammonia nitrogen and nitrite nitrogen had a great influence on the determination results,while phosphate and metaphosphate had little effect on the determination results.
作者
徐宇峰
郭鸣
王龙
李思敏
XU Yufeng;GUO Ming;WANG Long;LI Simin(College of Energy and Environmental Engineering,Hebei University of Engineering,Handan 056038;Chongqing Academy of Metrology and Quality Inspection,Chognqing 401120)
出处
《分析试验室》
CAS
CSCD
北大核心
2020年第3期272-277,共6页
Chinese Journal of Analysis Laboratory
基金
国家自然科学基金(51508149)
邯郸市科学研究与发展计划(1623209044-2)
中国博士后科学基金第65批面上项目(2019M650860)
河北省自然科学基金(E2019402410)资助。
关键词
CODCR
分析方法
响应面法
氮影响
磷影响
CODCr
measurement
response surface method
influence of nitrogen
influence of phosphorus