期刊文献+

Basic Physical Properties and Degradability of Tungsten Wire Fibers

下载PDF
导出
摘要 In order to explore the feasibility of tungsten filament as biomedical metal material,this article conducted a series of performance tests on two different thicknesses of black tungsten filament and two different thicknesses of white tungsten filament.It mainly tested the basic physical properties of the tungsten filament including the longitudinal cross-section of the fiber,the fiber diameter,the mechanical properties of the fiber and the biodegradability,and analyzed the results.The results showed that the breaking force of tungsten filament was about 3000MPa.And whether it was black tungsten filament or white tungsten filament,the larger the diameter,the greater the breaking force,and the breaking strength of the tungsten filament was much larger than the breaking strength of the steel wire.The larger the diameter of the tungsten filament,the slower the degradation rate.During the two months,the mass loss rate of the thick black tungsten filament was 59.40%,thin black tungsten filament was 83.88%,thick white tungsten filament was 47.39%,thin white tungsten filament was 72.29%,the degradation rate of thick tungsten wire was nearly half of the thin,and degradation mainly occured in the first months.
作者 朱烨佳 马颜雪 关国平 孟粉叶 李毓陵 ZHU Yejia;MA Yanxue;GUAN Guoping;MENG Fenye;LI Yuling(Engineering Research Center of Technical Textiles, Ministry of Education, Shanghai 201620, China;College of Textiles, Donghua University, Shanghai 201620, China)
出处 《Journal of Donghua University(English Edition)》 EI CAS 2020年第1期50-54,共5页 东华大学学报(英文版)
基金 Fundamental Research Funds of Central Universities,China(No.2232019G-06)。
  • 相关文献

参考文献3

二级参考文献74

  • 1WITTE F, KAESE V, HAFERKAMP H, SWITZER E, MEYER-LINDENBERG A, WIRTH C J, WlNDHAGEN H. In vivo corrosion of four magnesium alloys and the associated bone response [J]. Biomaterials, 2005, 26(17): 3557-3563.
  • 2XU L, YU G, ZHANG E, PAN F, YANG K. In vivo corrosion behavior of Mg-Mn-Zn alloy for bone implant application [J]. Journal of Biomedical Materials Research: Part A, 2007, 83(3): 703-711.
  • 3WAKSMAN R, PAKALA R, KUCHULAKANTI P K, BAFFOUR R, HELLINGA D, SEABRON R, TIO F O, WITTCHOW E, HARTWIG S, HARDER C. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries [J]. Catheterization and Cardiovascular Interventions, 2006, 68(4): 607-617.
  • 4PEUSTER M, HESSE C, SCHLOO T, F1NK C, BEERBAUM P, von SCHNAKENBURG C. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta [J]. Biomaterials, 2006, 27(28): 4955-4962.
  • 5PEUSTER M, WOHLSEIN P, BRIJGMANN M, EHLERDING M, SEIDLER K, FINK C, BRAUER H, FISCHER A, HAUSDORF G. A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into new zealand white rabbits [J]. Heart, 2001, 86(5): 563.
  • 6WAKSMAN R O N, PAKALA R, BAFFOUR R, SEABRON R, HELLINGA D, TIO F O. Short-term effects of biocorrodible iron stents in porcine coronary arteries [J]. Journal of Interventional Cardiology, 2008, 21(1): 15-20.
  • 7ZARTNER P, CESNJEVAR R, SINGER H, WEYAND M. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby [J]. Catheterization and Cardiovascular Interventions, 2005, 66(4): 590-594.
  • 8ERBEL R, DI MARIO C, BARTUNEK J, BONNIER J, de BRUYNE B, EBERLI F R, ERNE P, HAUDE M, HEUBLEIN B, HORRIGAN M. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial [J]. The Lancet, 2007, 369(9576): 1869-1875.
  • 9DI MARIO C, GRIFFITHS H U W, GOKTEK1N O, PEETERS N, VERBIST J A N, BOSIERS M, DELOOSE K, HEUBLEIN B, ROHDE R, KASESE V. Drug-eluting bioabsorbable magnesium stent [J]. Journal ofinterventional cardiology, 2004, 17(6): 391-395.
  • 10SCHRANZ D, ZARTNER P, MICHEL-BEHNKE I, AKIN'FORK H. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn [J]. Catheterization and Cardiovascular Interventions, 2006, 67(5): 671-673.

共引文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部