采用超声波强化零价铁/过硫酸钠体系(UV/Fe(0)/SPS)降解水中的1,2-二氯苯,考察了初始pH值、零价铁投加量、过硫酸盐投加量、超声波功率等对1,2-二氯苯降解的影响。实验结果表明,1,2-二氯苯降解的最佳实验条件为初始pH值为5,零价铁投加量为150mg·L-1,过硫酸盐投加量为200mg·L-1,1,2-二氯苯的去除率达到了91.1%。不同体系的对比实验显示,Fe(0)/US/SPS体系的1,2-二氯苯去除率显著高于Fe(0)/US、US/SPS与Fe(0)/SPS体系,超声波对Fe(0)/SPS体系有协同作用,可显著提升1,2-二氯苯的去除率。
The degradation of 1,2-dichlorobenzene in water by UV/Fe(0)/SPS was enhanced by ultrasound.The effects of initial pH value,dosage of zero valent iron,dosage of persulfate and ultrasonic power on the degradation of 1,2-dichlorobenzene were investigated.The results showed that the best experimental conditions for the degradation of 1,2-dichlorobenzene were as follows:the initial pH value was 5,the dosage of zero valent iron was 150 mg· L-1,the dosage of persulfate was 200 mg·L-1,and the removal rate of 1,2-dichlorobenzene reached 91.1%.The results showed that the removal rate of 1,2-dichlorobenzene in Fe(0)/US/SPS system was significantly higher than that in Fe(0)/US,US/SPS and Fe(0)/SPS system.Ultrasound had synergistic effect on Fe(0)SPS system,which could significantly improve the removal rate of 1,2-dichlorobenzene.
作者
廖书林
浦燕新
周梦凯
许龙霞
LIAO Shulin;PU Yanxin;ZHOU Mengkai;XU Longxia(Willie Environmental Group Co.,Ltd.,Changzhou Jiangsu 213125,China)
出处
《山西化工》
2020年第2期3-4,19,共3页
Shanxi Chemical Industry
基金
“水专项关键技术成果产业化二次开发与市场化推广研究课题”课题编号:2018ZX07208010。
关键词
超声波
零价铁
过硫酸钠
1
2-二氯苯
影响因素
ultrasound
zero valent iron
sodium persulfate
1,2-dichlorobenzene
influencing factors