摘要 在天然气输气管道工程中,紧急切断阀通常选用气液联动执行机构,但其结构复杂、价格昂贵;紧急放空阀常采用电动执行机构,但其在安全性方面存在不足。因此,有必要为安全仪表系统(SIS)阀寻找满足功能安全、结构简单并节省投资的其他类型执行机构。通过与气液联动执行机构、电液联动执行机构、气动执行机构及电动执行机构的性能和经济性比较,介绍了管道气直驱执行机构和其他类型执行机构的适用场合,并阐述了管道气直驱执行机构的概念、分类和应用情况。通过分析,得出了对于天然气管道工程中口径16英寸(1英寸=25.4 mm)或16英寸以下的紧急切断阀,管道气直驱执行机构更为适用的结论。这为以后的天然气长输管道工程中执行机构类型选择提供了参考和指导。 In natural gas transmission pipeline project,pneumatic-hydraulic actuator is commonly used for emergency shut-off valve,but it is complicated and expensive,and electric actuator is often used for emergency vent valve,however it has defects in safety.Therefore,it is necessary to find other types of actuators for the safety instrument system(SIS)valves,that satisfy the requirements of functional safety,simple structure and saving on investment.By comparing the performance and economical efficiency of pneumatic-hydraulic actuator,electrohydraulic actuator,pneumatic actuator and electric actuator with that of the pipeline gas direct-driven actuator,the applicable occasions of the pipeline gas direct-driven actuator and other types of actuator were described,and the concept,classification and application of the pipeline gas direct-driven actuator were expounded.Through analysis,it was concluded that the pipeline gas direct-driven actuator was more suitable for the emergency shutoff valve of 16"(1 inch=25.4 mm)or below in the natural gas pipeline project,which could be used as reference for actuator selection in the future natural gas long-distance pipeline project.
作者 孙金玲 SUN Jinling(Beijing Branch,Sinopec Petroleum Engineering Co. ,Ltd. ,Beijing 100096,China)
出处 《自动化仪表》 CAS 2020年第5期107-110,共4页 Process Automation Instrumentation
关键词 天然气 管道气直驱执行机构 气液联动执行机构 电液联动执行机构 气动执行机构 电动执行机构 输气管道 紧急关断 Natural gas Pipeline gas direct-driven actuator Pneumatic-hydraulic actuator Electro-hydraulic actuator Pneumatic actuator Electric actuator Gas transmission pipeline Emergency shutoff
  • 相关文献

参考文献3

二级参考文献6

  • 1乐嘉谦.仪表工手册.第2版.北京:化学工业出版社,2007
  • 2陆德民,张振基,黄步余.石油化工自动控制设计手册.第3版.北京:化学工业出版社,2001,136-138.
  • 3明赐东.调节阀计算、选型、使用.成都:成都科技大学出版社,1999.
  • 4中国石油管道公司.气液联动执行机构[J].仪表工(操作岗位高级资质认证)2014 (3): 111-116.
  • 5杨日永,康亮,彭振华.SHAFER气液联动执行机构维保探讨[J].科学之友(中),2010(3):25-26. 被引量:6
  • 6汪世军.Shafer气液联动阀执行机构功能与维护[J].油气储运,2010,29(4):296-298. 被引量:27

共引文献16

同被引文献46

引证文献7

二级引证文献9