摘要 随着智能电网的不断发展和完善,智能电能表作为计量电能的终端产品被广泛应用,而对其检定的自动化程度也越来越高,因此,智能电能表自动化检定流水线得到快速发展。与此同时,智能电能表自动化检定流水线的环境中,移动通信射频信号对电能表计量准确度的电磁辐射影响也逐渐引起了关注。为了研究射频信号对电能表计量的影响,文中分析了射频信号对电能表计量影响的干扰途径,分析了射频信号影响电能表计量的机理。测试了自动化检定流水线的环境中射频干扰信号的强度,基于干扰信号的调制方式建立了干扰信号数学模型,根据干扰信号数学模型和实测射频信号的功率谱,通过仿真分析确定了干扰信号对电能表的影响属于一种均匀性分布的噪声。建立了射频信号对电能表计量误差影响的数学模型,通过仿真分析电能表误差,给出智能电能表大规模自动化检定流水线射频信号的影响结果。 With the continuous development and improvement of smart grid,the smart electricity meters are widely used as terminal products for measuring electric energy,and the automation degree of their verification is also getting higher and higher.Therefore,the automatic verification pipeline of smart electricity meters has been rapidly developed.Meanwhile,the electromagnetic radiation effect of high-frequency radio signals of mobile communication on the metering accuracy of electricity meters is also gradually attracting attention in the environment of automatic verification pipeline of smart electricity meters.In order to study the influence of high-frequency RF signal on the metering of electricity meters,this paper firstly analyzes the interference path of the influence of RF signal on the metering of electricity meters,and analyzes the mechanism of the influence of RF signal on the metering of electricity meters.Secondly,the automatic detection line of high frequency radio frequency interference signal strength is tested,and the interference signal mathematical model is established based on the interference signal modulation mode,and then,according to the mathematical model and the measured interference signals of RF signal power spectrum,and the effect of interference signals of electricity meter belongs to a kind of uniformity of the distribution of noise is determined through the simulation analysis.Finally,the mathematical model of the influence of RF signal on the metering error of electricity meters is established,and the influence of RF signal on the large-scale automatic verification pipeline of smart electricity meters is given by analyzing the error of electricity meters through simulation.
作者 方正武 许中璞 王学伟 白静芬 卢达 Fang Zhengwu;Xu Zhongpu;Wang Xuewei;Bai Jingfen;Lu Da(School of Information Science and Technology,Beijing University of Chemical Technology,Beijing 100029,China;Wuwei Occupational College,Wuwei 733000,Gansu,China;China Electric Power Research Institute Co.,Ltd.,Beijing 100085,China)
出处 《电测与仪表》 北大核心 2020年第9期140-145,共6页 Electrical Measurement & Instrumentation
关键词 自动化检定流水线 电磁辐射 射频信号 电能表计量误差 automatic verification pipeline electromagnetic radiation RF signal metering error of electricity meter
  • 相关文献

参考文献10

二级参考文献73

共引文献59

同被引文献110

引证文献8

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部