介绍电解槽中氯酸盐含量过高的危害是:电流效率降低,设备腐蚀,螯合树脂损坏,在线分析仪分析结果不准确。给出氯酸盐分解工艺流程图。提出控制氯酸盐含量的方法有:增加氯酸盐分解槽和电解槽加酸量,降低淡盐水pH值。明确控制氯酸盐含量的注意事项。
The hazards of excess chlorate content in electrolyzers include the reduction of current efficiency,the corrosion of equipment,the damage of chelating resin,and the inaccurate results of on-line analyzer.The process flow chart of chlorate decomposition is given.The methods to control the chlorate content are as follows:increase the amount of acid added to chlorate decomposition tank and to electrolyzer,and reduce the pH value of depleted brine.The precautions for chlorate content control are defined.
作者
权耀宁
张黎峰
王洪江
QUAN Yaoning;ZHANG Lifeng;WANG Hongjiang(Inner Mongolia Zhonggu Mining Industry Co.,Ltd.,Erdos 016064,China)
出处
《氯碱工业》
CAS
2020年第5期18-21,共4页
Chlor-Alkali Industry
关键词
氯酸盐
电解槽
控制方法
改进
chlorate
electrolyzer
control method
improvement