摘要 通过使用MATLAB软件,设计了四开叉型微针阵列的掩模板图形,并利用仿真和掩模板图形补偿方法,改进了四开叉型微针阵列的掩模板图形,使得制备的四开叉型微针阵列的强度得到增加。采用两次移动X光曝光技术制备了聚甲基丙烯酸甲酯(PMMA)四开叉型微针阵列。利用毛细管现象,制备的四开叉型微针可以提取与血液性质类似的苯胺蓝溶液,验证了该微针阵列可以用来采血。通过将微针刺入聚氨酯薄膜上,测试施加的负荷来进行强度测试,验证了所制备的微针阵列有足够的强度,负荷为0. 4 N/针。 By using MATLAB software,mask pattern of quadruplets-microneedle is designed,and the mask pattern of quadruplets-microneedle is improved by simulation and mask pattern compensation method,so that the strength of the prepared quadruplets-microneedle is increased. PMMA quadruplets-microneedle is prepared by moving X-ray exposure technology twice. By using the capillary phenomenon,the quadruplets-microneedle array can extract the aniline blue solution,because the viscosity of the liquid is similar to that of blood,which proves that the microneedle array can be used for blood extraction. The strength test is carried out by inserting the micro needle into the polyurethane film and testing the applied load. It is verified that the prepared micro-needle array has sufficient strength and the load onto the microneedle is 0. 4 N/needle.
作者 王洁 金敏慧 蔡金东 吴文渊 李以贵 WANG Jie;JIN Minhui;CAI Jindong;WU Wenyuan;LI Yigui(School of Science,Shanghai Institute of Technology,Shanghai 201418,China;School of Mechanical Engineering,Shanghai Institute of Technology,Shanghai 201418,China)
出处 《传感器与微系统》 CSCD 2020年第6期70-72,76,共4页 Transducer and Microsystem Technologies
基金 国家自然科学基金资助项目(51035005) 上海市农委重点项目(沪农科创字(2018)第3-3号)。
关键词 移动X光光刻技术 聚甲基丙烯酸甲酯(PMMA)四开叉型微针 毛细管现象 moving X-ray lithography technology PMMA quadruplets-microneedle capillarity phenomenon
  • 相关文献

参考文献2

二级参考文献20

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部