期刊文献+

基于多普勒雷达传感器的人体体征检测 被引量:3

Detection of human body signs based on Doppler radar sensor
下载PDF
导出
摘要 针对非接触式人体体征检测中,由于信号微弱并且存在大量噪声的问题,设计了放大电路和滤波电路,实现对信号的放大、去噪;利用高精度模/数转换器(ADC)进行信号采集,通过MATLAB实现信号的处理;利用得到的电特性反向计算人体的体征信息。对设计的人体体征检测装置进行测试,实验结果表明:检测系统可有效检测单个静止人体的呼吸与心跳,最大有效工作距离为100 cm。 Aiming at the problem of weak signal and noise in non-contact human body sign detection,amplification and filtering circuits are designed to achieve signals amplification and de-noising function.High precision analog to digital converter(ADC)is used to acquire signals,and MATLAB is used to process signals.The obtained electrical characteristics are used to calculate the body signs in reverse.Experimental result shows that the designed human body signs detection device can effectively detect the breathing and heartbeat of a single stationary human body,and the maximum effective working distance is 100 cm.
作者 刘旭阳 崔恒荣 刘钊 朱芸桢 刘涛 王煜伟 LIU Xuyang;CUI Hengrong;LIU Zhao;ZHU Yunzhen;LIU Tao;WANG Yuwei(College of Information Science and Technology,Donghua University,Shanghai of weak signal and the noise,201620,China)
出处 《传感器与微系统》 CSCD 2020年第5期137-139,共3页 Transducer and Microsystem Technologies
关键词 多普勒雷达 人体体征 放大 滤波 Doppler radar human body signs amplification filtering
  • 相关文献

参考文献9

二级参考文献84

  • 1罗志增,赵鹏飞.非线性PCA在表面肌电信号特征提取中的应用[J].传感技术学报,2007,20(10):2164-2168. 被引量:6
  • 2路国华,王健琪,杨国胜,荆西京.生物雷达技术的研究现状[J].国外医学(生物医学工程分册),2004,27(6):368-370. 被引量:25
  • 3路国华,杨国胜,王健琪,荆西京.雷达式生命探测仪中人体数量识别技术的研究[J].北京生物医学工程,2005,24(1):29-32. 被引量:12
  • 4Stephen J, Redmond C H. Cardiorespiratory-based sleep staging in subjects with obstructive sleep apnea [ J ]. IEEE Transactions on Biomedical Engineering,2006,53 (3) :485 -496.
  • 5Buist M. Association between clinically abnormal observations and subsequent in-hospital mortality : A prospective study [ J ]. Resuci- ration ,2004,62 (2) : 137 -141.
  • 6Watanabe T,Watanabe K. Noncontact method for sleep stage esti- mation[ J ]. IEEE Transactions on Biomedical Engineering,2004, 51(10) :1735 -1748.
  • 7Chee Y J, Han J M, Youn J W, et al. Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements[ J ]. Physiological Measurement,2005, 26(4) :413 -422.
  • 8Townsend D, Hohzman M, Goubran R, et al. Relative thresholding with under-mattress pressure sensors to detect central apnea[ J]. IEEE Transactions on Instrumentation and Measurement,2011, 60(10) :3281 -3289.
  • 9Shin J H, Chee Y J, Jeong D U,et al. Nonconstrained sleep moni- toring system and algorithms using air-mattress with balancing tube method[ J]. IEEE Transactions on Information Technology in Biomedicine ,2010,14 ( 1 ) : 147 -156.
  • 10Mostarac P, Mataric R, Jurcevic M, et al. System for monitoring and fall detection of patients using mobile 3-axis accelermneters sensors[ C]//IEEE International Workshop on Medical Measure- ments and Applications,2011:456 -459.

共引文献50

同被引文献21

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部