摘要
介绍医院重要场所UPS的电气设计,包括UPS容量及应急时间的选择、机房面积、机房设置要求、供电距离等,并以某项目为例对分区集中设置、完全集中设置与末端分散设置三种方案进行比较。
This paper introduces the electrical design of UPS in important places of the hospital,including the selection of UPS capacity and emergency time,room area,room setting requirements,power supply distance,etc.,and compares the three schemes of centralized partition setting,complete centralized setting and end decentralized setting with an example.
作者
肖跃红
Xiao Yuehong(Hunan Architectural Design Institute Co.,Ltd.,Changsha 410012,China)
出处
《智能建筑电气技术》
2020年第2期46-49,共4页
Electrical Technology of Intelligent Buildings
关键词
UPS容量计算
应急供电时间
设置方式
设置要求
房间面积
供电距离
UPS capacity calculation
emergency power supply time
setting methods
setting requirements
room area
power supply distance