摘要 现有的暂态量选线法易受复杂故障条件影响。提出了一种以故障暂态零序电流差异程度为判据的选线方法,利用Hausdorff距离算法,对线路零序电流间的不匹配度进行求解。构造了不匹配度矩阵,进而得到线路的不匹配度和与不匹配度商,以表征线路零序电流间的差异程度。当不匹配度商低于阈值时,判定母线故障;反之,则判定不匹配度和的最大值对应的线路故障。仿真及实例验证结果表明,该方法能够准确地对母线故障与馈线故障进行区分,且不受复杂故障因素的影响。 The existing transient line selection methods are vulnerable to complex fault conditions. In this paper,a fault line selection method is proposed based on the criterion of difference degree between zero-sequence currents in the fault transient state. Hausdorff distance algorithm is used to calculate the mismatch degree between zero-sequence currents.A matrix of mismatch degree is constructed,so that the mismatch degree of lines and the quotient of mismatch can be obtained to characterize the difference between zero-sequence currents. When the quotient of mismatch is lower than the threshold,the bus fault can be judged;otherwise,the line corresponding to the maximum value of sum of mismatch degrees can be judged to be under a fault condition. Simulation results of a practical example show that this method can accurately distinguish bus fault from feeder fault,and it is not affected by complex fault factors.
作者 魏鑫 舒乃秋 WEI Xin;SHU Naiqiu(School of Electrical Engineering and Automation,Wuhan University,Wuhan 430072,China)
出处 《电力系统及其自动化学报》 CSCD 北大核心 2020年第5期133-142,共10页 Proceedings of the CSU-EPSA
关键词 小电流接地系统 HAUSDORFF距离 波形 选线 不匹配度 small-current grounding system Hausdorff distance waveform line selection mismatch degree
  • 相关文献

参考文献13

二级参考文献126

共引文献551

同被引文献135

引证文献13

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部