CA型新一代天气雷达触发器故障分析及处理 被引量:3

Failure analysis and solution to problems of CINRAD/CA trigger
下载PDF
导出
摘要 天气雷达的触发器为调制器可控硅提供触发放电信号,触发器故障后将导致调制器人工线无法放电,发射机停止工作。通过对六盘水新一代天气雷达(CINRAD/CA)多次触发器故障的原因分析,发现触发器控制板3A11A1上Q1场效应管(IRFPS43N50K)被击穿,栅极、漏极与源极之间两两短路,是导致R23过热烧毁的主要原因。在分析电路图和信号流程的基础上,结合六盘水雷达触发器故障,介绍了类似故障的处理方法,旨在使技术保障人员掌握触发器组件的原理和维修方法,提高排除此类故障能力。 The trigger of CINRAD/CA provides the trigger discharge signal for the modulator of thyristor.If the trigger malfunctions,the modulator artificial line will not discharge and the transmitter will stop working.The causes of multiple failures of the CINRAD/CA in Liupanshui were analzed,it is found that the breakdown of the Q1 field effect transistor(IRFPS43 N50 K)on the trigger control board 3 A11 A1 and the short circuit between the gate,drain and source are the main reasons for the overheating and burning of R23.Based on the analysis of the circuit diagram and signal flow,combined with the trigger fault of Liupanshui CINRAD/CA,the processing method of similar fault was introduced in order to make the technical support personnel master the principle and maintenance method of the trigger component,and improve the ability to eliminate such failure.
作者 陈昌文 孙传东 蒋仕华 侯亮 黄天福 CHEN Changwen;SUN Chuandong;JIANG Shihua;HOU Liang;HUANG Tianfu(Liupanshui Meteorological Bureau of Guizhou Province,Liupanshui 553000,China;Beijing Minshida Radar Co.,Ltd.,Beijing 100000,China)
出处 《中低纬山地气象》 2020年第2期102-105,共4页 Mid-low Latitude Mountain Meteorology
关键词 CINRAD/CA 触发器 故障 方法 CINRAD/CA trigger failure method
  • 相关文献

参考文献1

二级参考文献2

  • 1斯科尔尼克MI.雷达手册[M].北京:国防工业出版社,1978..
  • 2戈隐.雷达接收机技术[M].北京:电子工业出版社,2005:234-242.

共引文献40

同被引文献28

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部