摘要
根据JGJ 57—2016《剧场建筑设计规范》的要求,结合上海交响音乐厅工程项目,从降噪声、抗电磁干扰、设计优化和研究方面探讨了观演建筑中配合工艺的电气设计,可为类似观演建筑的电气设计提供参考。
According to JGJ 57—2016,based on the engineering case of Shanghai Symphony Hall,the electrical design of the matching technology was discussed in aspects of noise reduction,anti-electromagnetic interference,design optimization and research.It can provide references for electrical design of similar performance buildings.
作者
王坚
WANG Jian(Tongji Architectual(Group)Co.,Ltd.,Shanghai 200092,China)
出处
《现代建筑电气》
2020年第4期44-47,共4页
Modern Architecture Electric
关键词
上海交响音乐厅
防噪声干扰
抗电磁干扰
设计优化
Shanghai Symphony Hall
anti-noise interference
anti-electromagnetic interference
design optimization