期刊文献+

关于双源CT临床应用现状的探讨 被引量:1

Discussion on the clinical application of dual source CT
下载PDF
导出
摘要 随着医疗设备的迅速更新发展,临床各疾病的检查方式开始有了新的选择。近年来双源电子计算机断层扫描(DSCT)技术受到的关注越来越多,这一新技术在临床诊断、评估疾病的应用上突破了传统CT的多项技术弊端。本文介绍了DSCT的技术原理及部分功能,如估计组织内的成分及含量、去骨及钙化技术、进行完全同步的双能量CT(DECT)扫描,并对DSCT目前的临床应用做以综述。 With the rapid development of medical equipment,the examination Methods for clinical diseases have begun to have new choices.In recent years,dual-source computed tomography(DSCT)technology has received more and more attention.This new technology has broken through many technical drawbacks of traditional CT in clinical diagnosis and evaluation of diseases.This paper introduces the technical principles and some functions of DSCT,such as estimating the composition and content of tissue,deboning and calcification techniques,performing fully synchronized dual-energy CT(DECT)scanning,and reviewing the current clinical application of DSCT.
作者 邱赫 曹绍东 高伟 Qiu He;Cao Shaodong;Gao Wei(Fourth Affiliated Hospital of Harbin Medical University,Harbin,Heilongjiang 150001,China)
出处 《影像研究与医学应用》 2020年第12期1-3,共3页 Journal of Imaging Research and Medical Applications
关键词 双源CT 双能量CT CT冠脉动脉造影 冠状动脉疾病 Dual-source CT Dual-energy CT CT coronary angiography Coronary artery disease
  • 相关文献

参考文献4

二级参考文献17

  • 1Flohr T G, McCollough C H, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system [J]. Eur Radiol, 2006, 16:256-268.
  • 2Flohr T G, Stierstorfer K, Ulzheimer S, et al. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot[J]. Med Phys, 2005, 32:2536-2547.
  • 3Raff G L, Gallagher M J, O'Neill W W, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography [J]. J Am Coll Cardiol, 2005, 46:552-557.
  • 4Flohr T G, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image-reconstruction techniques [J]. Radiology, 2005, 235:756-773.
  • 5Achenbach S, Ropers D, Kuettner A, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience [J]. Eur J Radiol, 2006, 57:331-335.
  • 6Wintersperger B J, Nikolaou K, van Ziegler F, et al. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed [J]. Invest Radiol, 2006, 41:436-442.
  • 7Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control[J]. Eur Radiol,2006,16:2739- 2747.
  • 8Johnson T R, Krauss B, Sedlmair M, et al. Material differentiation by dual energy CT: initial experience[J]. Eur Radiol,2007,17:1510- 1517.
  • 9丁倩芸,李小虎,刘斌,张超,余永强.双能量CT区分不同成分泌尿系结石[J].中国介入影像与治疗学,2014,11(4):252-255. 被引量:5
  • 10锁咏梅,宋贤亮,邱晓晖,章辉庆.双能量CT与MRI诊断交叉韧带损伤的对照研究[J].安徽医学,2016,37(5):569-571. 被引量:12

共引文献84

同被引文献11

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部