新冠肺炎隔离病区手触式消毒剂按钮新型冠状病毒污染调查 被引量:4

2019-nCoV contamination on hand-touched buttons of alcohol-based hand rub in COVID-19 isolation ward area
下载PDF
导出
摘要 目的了解某区域性新型冠状病毒肺炎定点救治医院隔离病区手触式速干手消毒剂(以下简称手消)按钮新型冠状病毒污染状况,为指导隔离病区消毒提供循证依据。方法对该隔离区内5个区域(确诊病房、病区内走廊、第一缓冲间、第二缓冲间、清洁区)手触式手消按钮进行采样,采用逆转录聚合酶链反应(RT-PCR)检测标本中新型冠状病毒污染情况。结果共采集76份手消按钮标本,隔离区新型冠状病毒污染率为10.53%,其中确诊病房内污染率14.29%,病区内走廊污染率12.50%;第一缓冲、第二缓冲区、清洁区污染率均为0。结论该隔离病区病房内手消按钮新型冠状病毒污染严重,需要加强清洁消毒,并建议隔离病区使用手背按压,有条件的医疗机构宜使用感应式手消出液器或洗手感应监测仪。 Objective To understand 2019-nCoV contamination on hand-touched buttons of alcohol-based hand rub in the isolation ward area of a regional coronavirus disease 2019(COVID-19)treatment hospital,and provide evidence for guiding disinfection in isolation ward area.Methods Hand-touched buttons of alcohol-based hand rub in 5 regions of the isolation ward area(confirmed ward,ward corridor,first buffer room,second buffer room,clean zone)were sampled,and contamination in specimens were detected with reverse transcription polymerase chain reaction(RT-PCR).Results A total of 76 button specimens were collected,2019-nCoV contamination rate in isolation ward area was 10.53%,contamination rates of buttons in confirmed ward and ward corridor were 14.29%and 12.50%respectively,contamination rates in the first buffer zone,the second buffer zone,and clean zone were all 0%.Conclusion Hand-touched buttons of alcohol-based hand rub in this isolation ward area are seriously contaminated by 2019-nCoV,cleaning and disinfection needs to be strengthened,it is suggested that buttons in isolation ward area should be pressed by the back of the hand,if medical institution is conditional,inductive liquid outlet and hand-washing sensor monitor should be used.
作者 陈雪琴 郭晓华 谭明伟 闫小娟 饶俊莉 李晓蕾 李兴挺 刘晞照 CHEN Xue-qin;GUO Xiao-hua;TAN Ming-wei;YAN Xiao-juan;RAO Jun-li;LI Xiao-lei;LI Xin-ting;LIU Xi-zhao(Department of Healthcare-associated Infection Management,Chongqing Three Gorges Central Hospital,Chongqing 404000,China)
出处 《中国感染控制杂志》 CAS CSCD 北大核心 2020年第6期510-512,共3页 Chinese Journal of Infection Control
关键词 新型冠状病毒肺炎 新型冠状病毒 病毒污染 手消毒剂按钮 coronavirus disease 2019 2019-nCoV virus contamination hand disinfectant button
  • 相关文献

参考文献9

二级参考文献46

  • 1葛忆琳,宦彭成.过氧化氢的消毒作用及其应用[J].上海预防医学,1999,11(11):517-518. 被引量:20
  • 2张朝武,王国庆,姚玉红.SARS-CoV对外环境中理化因子的抵抗力和稳定性[J].现代预防医学,2004,31(1):1-3. 被引量:5
  • 3高君,张琳.两种喷雾器喷雾过氧化氢对空气消毒效果观察[J].中国消毒学杂志,2007,24(3):250-251. 被引量:11
  • 4.消毒技术规范[S].[S].中华人民共和国卫生部,2002,11..
  • 5Gray J, Omar N. Nosoeomial infection in neonatal intensive care units in developed and developing countries: how can we narrow the gap.'? [J]. J Hosp Infect, 2013, 83 (3) : 193- 195.
  • 6Auriti C, Ronchetti MP, Pezzotti P, et al. Determinants of nosocomial infection in 6 neonatal intensive care units: an I- talian rnulticenter prospective cohort study [J]. Infect Con- trol Hosp Epidemiol, 2010, 31 (9).. 926-933.
  • 7Weber DJ, Anderson D, William A, etal. The role of the surface environment in heahhcare-associated infections [J]. Curt Opin Infect Dis, 2013, 26 (4) : 338- 344.
  • 8Huslage K, Rutala WA, Sickbert-Bennett A. Quantitative approach to defining "high-touch" surfaces in hospitals [J]. Infect Control Hosp Epldemiol, 2010, 31 (8) : 850-653.
  • 9Takei Y, Yokoyama K, Katano H, et al. Molecular epide- miological analysis of methicillin-resistant Staphylococci in a neonatal intensive care unit [J]. Biocontrol Sci, 2010, 15 (4): 129-138.
  • 10Stiefel U, Cadnum JL, Eskstein BC, et al. Contamination of hands with methlcillin resistant Staphylococcus aureus after contact with environmental surface and after contact with the skin of colonized patients [J]. Infect Control Hosp Epi- demiol, 2011, 32 (2) 185 -187.

共引文献540

同被引文献43

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部