摘要 介绍机房空调系统气流理论、气流结构的优化和室外冷源的利用方式,结合多年空调运行维护的经验方法,创新性地提出了机房纵向隔离效果的气流结构的理论方法和对室外冷源利用的方法研究,为数据中心机房、核心机房、汇聚机房乃至基站机房提供了节能环保新技术方面的建议。 This paper introduces the theory of air flow,the optimization of air flow structure and the utilization of outdoor cold source.Combined with many years of experience in air conditioning operation and maintenance,the theoretical method of air flow structure with longitudinal isolation effect of the machine room and the method research on the utilization of outdoor cold source are innovatively put forward,which provides suggestions on new energy-saving and environmental protection technologies for data center machine room,core machine room,convergence machine room and even base station machine room.
作者 张礼 ZHANG Li(Network Department of Anqing Mobile Branch,Anqing 246003,China)
出处 《通信电源技术》 2020年第7期138-142,共5页 Telecom Power Technology
关键词 通信机房 气流 隔断 communication room air flow partition