期刊文献+

实时三维超声心动图Heart Model模式定量评价左室容量及左室射血分数 被引量:3

Quantitative evaluation of left ventricular volume and left ventricular ejection fraction by real-time 3D echocardiogram Heart Model
下载PDF
导出
摘要 目的探讨三维超声心动图全自动左心定量技术(three-dimensional echocardiography Heart Model,3D-HM)在左室收缩功能评估中的应用价值。方法选取我院2018年1月~2019年5月健康体检的正常成年人58例,男24例,女34例。均采用常规M型超声、双平面辛普森法、二维心功能定量(2DQ)、三维自动化心功能定量(3DQA)、3D-HM分别测量左室舒张末期容积(LVEDV)、收缩末期容积(LVESV)、射血分数(LVEF),对比分析3D-HM与其他方法测量的差异性和相关性。结果ESV:3D-HM组较M型超声、Bi-plane、X-plane、2DQ、3DQA组ESV值偏高,差异具有显著统计学意义(P<0.01);EDV:3D-HM组较Bi-plane、X-plane、2DQ、3DQA组EDV值偏高,差异具有显著统计学意义(P<0.01),较M型超声组EDV值差异无统计学意义(P>0.05);EF:3D-HM组较M型超声、Bi-plane、2DQ组EF值偏低,差异具有显著统计学意义(P<0.01),较X-plane、3DQA组EF值差异无统计学意义(P>0.05)。相关性分析:ESV:3D-HM组与M型超声、Bi-plane、2DQ、X-plane、3DQA组ESV值呈正相关关系(P<0.05);EDV:3D-HM组与M型超声、Bi-plane、X-plane、2DQ、3DQA组EDV值呈正相关关系(P<0.05);EF:3D-HM组与M型超声、Bi-plane、2DQ、3DQA组EF值呈正相关(P<0.05),与X-plane组EF值无直线相关关系。结论3D-HM可以准确、快速量化左室容量及射血分数,在左心收缩功能评价中具有较高的临床价值。 Objective To investigate the application value of three-dimensional echocardiography Heart Model(3D-HM)in the assessment of left ventricular systolic function.Methods A total of 58 normal adults in our hospital from January 2018 to May 2019 were selected,including 24 males and 34 females.Left ventricular end-diastolic volume(LVEDV),end-systolic volume(LVESV)and ejection fraction(LVEF)were measured by conventional M-mode ultrasound,biplane Simpson method,two-dimensional cardiac function quantification(2DQ),three-dimensional automated cardiac function quantification(3DQA),and 3D-HM.The differences and correlations between 3D-HM and other methods were compared and analyzed.Results ESV:3D-HM group had higher ESV value than the M-mode ultrasound,Bi-plane,X-plane,2DQ,and 3DQA group,and the difference was statistically significant(P<0.01).The EDV:The EDV value in the 3D-HM group was higher than that in the Bi-plane,X-plane,2DQ,and 3DQA group,and the difference was statistically significant(P<0.01);and there was no significant difference in EDV value between the 3D-HM group and the M ultrasound group(P>0.05).EF:3D-HM group had lower EF value than M-mode ultrasound,Bi-plane,and 2DQ groups,and the difference was statistically significant(P<0.01).There was no significant difference in the EF value between 3D-HM group and X-plane,3DQA group(P>0.05).Correlation analysis:ESV:3D-HM group had positive correlation with ESV value of M-mode ultrasound,Bi-plane,2DQ,X-plane,and 3DQA group(P<0.05);EDV:3D-HM group was positively correlatedwith the EDV value of M-mode ultrasound,Bi-plane,X-plane,2DQ,and 3DQA group(P<0.05).EF:3D-HM group was positively correlated with the M-mode ultrasound,Bi-plane,2DQ,and 3DQA group(P<0.05),and there was no linear correlation in the EF values between the 3D-HM group and the X-plane group.Conclusion 3D-HM can accurately and quickly quantify left ventricular volume and ejection fraction,and has high clinical value in the evaluation of left ventricular systolic function.
作者 万野 WAN Ye(Department of Ultrasound Medicine,Neijiang First People's Hospital in Sichuan Province,Neijiang641000,China)
出处 《中国现代医生》 2020年第12期132-135,共4页 China Modern Doctor
关键词 左室容量 左室射血分数 Heart Model 超声心动描记术 Left ventricular volume Left ventricular ejection fraction Heart Model Echocardiography
  • 相关文献

参考文献4

二级参考文献35

共引文献45

同被引文献41

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部