摘要
介绍了国内核电厂消防设计相关标准对电缆隧道内灭火系统选型要求存在的异同,以及水喷雾与自动喷水灭火系统两者之间基本设计参数的差别。从分析中外电缆隧道灭火规范的发展历程及主要差异入手,提出采用快速响应洒水喷头,并结合当前市场上阻燃材料在电缆绝缘和外护套的普遍应用,给出综合性优劣的排序,供设计和建设方选择采用。
The paper introduces the differences in the requirements of relevant design codes for both domestic and foreign NPPs on the type selection of cable tunnel fire extinguishing systems,and the differences in designs parameters between water spray and automatic water sprinkler systems.It also analyzes the development history of domestic and foreign cable tunnel firefighting codes and main differences between them,proposes the use of fast-response water sprinkler,and based on the widespread applications of fire retardant materials in cable insulation and outer sheaths in current market,presents a comprehensive ranking order of advantages and disadvantages,providing reference for design and construction organizations in selection decision making.
作者
马逸萍
王金龙
张龙洲
孙一奇
程道仓
MA Yiping;WANG Jinlong;ZHANG Longzhou;SUN Yiqi;CHENG Daocang(Training Center of State Grid Anhui Electric Power Co.Ltd.,Hefei 230022;China Nuclear Power Design Co.,Ltd.(Shenzhen),Shenzhen 518000;CGN Huizhou Nuclear Power Co.,Ltd.,Huizhou 516000;Hualong Pressurized Water Reactor Technology Co.,Ltd.,Beijing 100036)
出处
《电力安全技术》
2020年第5期12-18,共7页
Electric Safety Technology
关键词
核电厂
电缆隧道
水喷雾
自动喷水
快速响应洒水喷头
设计标准
nuclear power plant
cable tunnel
water spray
automatic water sprinkling
rapid-response sprinkler
design criteria