摘要
针对反应堆循环冷却水系统中的差压式过滤器易发生堵塞的问题,介绍了反应堆现有安装调试后的差压式过滤器结构和工作原理。通过分析差压式过滤器滤水能力的影响因素,研究了不同运行参数对差压式过滤器滤水量的影响,得出最优的运行参数,有效保障反应堆二回路系统用户的供水需求。
Aiming at the plugging problem of the differential pressure filter in the reactor closed circulating cooling water system,the structure and working principle of the differential pressure filter after the reactor's existing installation and commissioning are introduced.By analyzing the influencing factors of the water filtration capacity of the differential pressure filter,this paper studies the influence of different operating parameters on the water filtration capacity of the differential pressure filter,and obtains the optimal operating parameters to effectively guarantee the water supply needs of the users of the reactor's secondary circuit system.
作者
曹宇
雷超
陈庆旭
魏大明
胡启帅
周金昊
高俭
杨松
CAO Yu;LEI Chao;CHEN Qingxu;WEI Daming;HU Qishuai;ZHOU Jinhao;GAO Jian;YANG Song(Nuclear Power Institute of China,Chengdu 610041,China)
出处
《机械工程师》
2020年第6期61-63,共3页
Mechanical Engineer
关键词
二回路系统
差压式过滤器
运行参数
滤水量
secondary circuit system
differential pressure filter
operating parameters
water filtration capacity