摘要 变压器高压侧采用电缆出线,能够有效减小变电室的空间尺寸,减少建设成本和土地占用。介绍了现有的典型结构设计,分析了其优缺点,提出了进一步结构优化方案,降低变压器高度,优化引线结构后,取消油油套管出线,变压器线圈高压侧引线出头直接连接至电缆插拔头底座上。实际应用表明,在降低高度的同时简化了安装结构,并降低生产制造成本。 The use of cable outlets on the high-voltage side of the transformer can effectively reduce the space dimensions of the substation,construction costs and land occupation.In this paper the existing typical structural design is introduced,its advantages and disadvantages are analyzed,and further structural optimization schemes are proposed to reduce the height of the transformer.After optimizing the lead structure,the oil bushing outlet is eliminated,and the high-voltage side lead outlet of the transformer coil is directly connected to the cable plug on the head base.Practical application shows that while reducing the height,it simpli fies the installation structure and reduces production costs.
作者 宋新勤 栗润祥 张全友 SONG Xin-qin;LI Run-xiang;ZHANG Quan-you(Chint Electric Co.,Ltd,Shanghai 201614,China)
出处 《电工电气》 2020年第6期59-61,68,共4页 Electrotechnics Electric
关键词 变压器 电缆插拔头 优化 transformer cable plug optimization