摘要 牡蛎主要生活在近海地区,位置稳定、流动性小,它们在滤食水中生物的同时也会将水体中的污染物聚集在体内,导致体内重金属含量升高。牡蛎是制造耗油的主要原料,因此,对蚝油中重金属铅含量的检测很有必要。试验建立了湿法消解-ICP-MS法测定蚝油中铅含量的方法。以扇贝粉作为质控样,优化了测定方法中的样品称样量、消解温度、硝酸加入量、高氯酸加入量等因素,在单因素试验的基础上采用正交试验得出最优组合,即样品称样量为0.9 g、消解温度为180℃、硝酸加入量为9 mL、高氯酸加入量为2.5 mL,在此条件下,质控样中铅测定值为0.119 mg/kg。该方法避免了高盐类样品背景干扰,操作简单,准确可靠,适用于贝类及贝类制品中铅含量的测定。 Oysters mainly live in the coastal area,with stable location and low mobility.They collecte pollutants in the water,resulting in the increase of heavy metal content in the body.Oysters were the main raw material for oil consumption.Therefore,it was necessary to detect the content of heavy metal lead in oyster sauce.The wet digestion-ICP-MS determination of lead in oyster sauce was established.Scallop powder as a quality control sample was used and the condition of wet digestion was optimized such as sampling,nitric acid addition,digestion temperature,perchloric acid addition.The optimal combination was obtained by orthogonal test on the basis of single factor.The optimal combination was that the sample addition was 0.9 g,the digestion temperature was 180℃and the nitric acid content was 9 mL,and the perchloric acid content was 2.5 mL.Under this condition,the determination content of lead in quality control sample was 0.119 mg/kg.This method avoids the background interference of high salt samples,is simple,accurate and reliable,and is suitable for the determination of lead in shellfish and shellfish products.
作者 刘超 景赞 吕雪梅 代雨心 LIU Chao;JING Zan;LV Xue-mei;DAI Yu-xin(Leshan Institute for Food and Drug Control,Leshan 614000,China;Leshan Normal University,Leshan 614000,China)
出处 《中国果菜》 2020年第5期75-78,共4页 China Fruit & Vegetable
关键词 蚝油 湿法消解 电感耦合等离子体质谱 Oyster sauce wet digestion ICP-MS lead
  • 相关文献

参考文献10

二级参考文献38

  • 1魏运金.酱油中铅含量的测定[J].福建分析测试,2004,13(2):1960-1961. 被引量:3
  • 2杨文英,王宝旺,籍术良.石墨炉原子吸收法直接测定酱油中的铅[J].中国卫生检验杂志,2007,17(6):1027-1028. 被引量:17
  • 3杨惠芬 李明元.食品卫生理化检验标准手册[M].北京:中国标准出版社,1997.115.
  • 4酱油卫生标准分析方法[M].北京:中国标准出版社,2003:317-323.
  • 5杨啸涛.原子吸收分析中的背景吸收及其校正[M].北京:北京大学出版社,1988.
  • 6[2]GB 5009.1996.12.
  • 7邓少平,田师一.电子舌技术背景与研究进展[J].食品与生物技术学报,2007,26(4):110-116. 被引量:58
  • 8郭德齐 张敏.氢化物-无色散原子荧光法测定人发中的铅含量.分析测试报,1994,11(6):51-52.
  • 9Deding J.prog.analysst.atom.Spectrose,11:251.
  • 10.中华人民共和国国家标准,食品卫生检验方法理化部分[J].第1版[M].北京:中国标准出版社,.45.

共引文献73

同被引文献85

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部