打叶复烤冷凝水疏水系统阀件内泄检测研究

Research on Valve Internal Leakage Detection of Condensate Drainage System for Threshing and Redrying
下载PDF
导出
摘要 本文针对打叶复烤车间冷凝水疏水系统阀件内泄检测进行研究,通过温度检测装置的研发、安装及使用,实现了对冷凝水疏水系统阀件内泄的时时检测,并通过设备区域的划分和区域性温度检测装置的安装,实现了疏水系统阀件内泄的精准检测,提高了修理人员对疏水系统阀件内泄的响应速度,降低了饱和蒸汽能源损耗,保证了产品质量。 In this paper,the valve leakage detection of condensate drainage system in the threshing and redrying workshop is studied.Through the development,installation and use of the temperature detection device,the valve leakage detection of condensate drainage system is realized at any time,through the division of the equipment area and the installation of the regional temperature detection device,the accurate detection of the inner leakage of the valve in the drainage system is realized,and the response speed of the Repairman to the inner leakage of the valve in the drainage system is improved,the energy loss of saturated steam is reduced and the product quality is guaranteed.
作者 李红梅 杨家华 山俊贻 蔡尤东 LI Hong-mei;YANG Jia-hua;SHAN Jun-yi;CAI You-dong(HONGYUNHONGHE Tobacco(Group)CO.LTD.Honghe Cigarette Factory,Honghe,Yunnan 652399)
出处 《新型工业化》 2020年第3期158-161,共4页 The Journal of New Industrialization
关键词 打叶复烤 冷凝水 疏水系统 温度检测 Threshing and redrying Condensate Drainage system Temperature detection
  • 相关文献

参考文献10

二级参考文献40

  • 1袁镇福,吴骅鸣,浦兴国,周洁,桑如波,李根银,张永苗.基于传热原理的电厂阀门泄漏量计算方法[J].动力工程,2004,24(5):725-728. 被引量:14
  • 2席增雪.疏水阀在蒸汽系统的应用[J].机电信息,2005(20):32-33. 被引量:7
  • 3陈曦丽,解清超.凝结水回收的节能效益[J].应用能源技术,2007(1):44-45. 被引量:2
  • 4蔡尔辅.石油化工管道设计[M].北京:化学工业出版社,2004.
  • 5GB/T(16903~16908)-2005锅炉用水和冷却水分析方法[S].北京:中国标准出版社,2005.
  • 6GB5750-85生活饮用水标准检测法[S].北京:中国标准出版社,1985.
  • 7东北电力设计院.GB/T50102-2003工业循环水冷却设计规范[M].北京:中国计划出版社,2003.
  • 8姜启源,谢金星,叶俊.数学模型[M].北京:高等教育出版社,2011.
  • 9钱颂文.换热器设计手册[M].北京:化学工业出版社,2006.
  • 10刘银河.蒸汽凝结水的回收及利用[M].北京:化学工业出版社,2007.