摘要 随着人们对辐射造成身体损害认识增加及多层螺旋CT探测器的发展使低辐射剂量CT肺动脉扫描技术受到广泛关注,低辐射剂量CT肺动脉血管成像可采取多种措施个体化方案扫描可简单有效的降低辐射剂量;前瞻性心电门控减少呼吸运动伪影使图像质量更佳;迭代重建算法保证了辐射剂量下降的同时降低图像噪声满足临床诊断需求。低辐射剂量意识对于降低辐射造成身体的损害至关重要。 With the development of multi-slice spiral CT detector and the recognition of radiation-induced physical damage,low-dose CT pulmonary artery angiography has attracted wide attention.There are many measures for low-dose CT pulmonary artery angiography individualized scanning can reduce radiation dose simply and effectively;prospective ECG-gated can reduce respiratory motion artifacts.Iterative reconstruction algorithm ensures that radiation dose decreases while reducing image noise to meet the needs of clinical diagnosis.Low radiation awareness is essential to reduce radiation damage to the body.
作者 郭亚哲(综述) 朱月香(审校) GUO Yazhe;ZHU Yuexiang(Graduate School of Hebei North University, Zhangjiakou 075000, P.R.China;Department of CT, First Affiliated Hospital of Hebei North University, Zhangjiakou 075000, P.R.China)
出处 《医学影像学杂志》 2020年第5期847-850,共4页 Journal of Medical Imaging
关键词 肺栓塞 肺动脉 体层摄影术 X线计算机 辐射剂量 Pulmonary embolism Pulmonary artery Tomography,X-ray computed Radiation dose
  • 相关文献

参考文献12

二级参考文献83

  • 1李真林,杨志刚,郭应坤,余建群,李媛,陈宪,谈伟.管电流调制技术在多层螺旋CT胸部检查中的应用评价[J].中国医学影像技术,2006,22(6):858-860. 被引量:7
  • 2Marten K,Engelke C,Funke M,et al.ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism[J].Clin Radiol,2003,58(11):862-868.
  • 3Scheffel H,Alkadhi H,Leschka S,et al.Low-dose CT coronary angiography in the step-and-shoot mode:diagnostic performance[J].Heart,2008,94(9):1132-1137.
  • 4Ghaye B,Szapiro D,Mastora I,et al.Peripheral pulmonary arteries:how far in the lung does multi-detector row spiral CT allow analysis?[J].Radiology,2001,219(3):629-636.
  • 5Hofmann LK,Zou KH,Costello P,et al.Electrocardiographically gated 16-section CT of the thorax:cardiac motion suppression[J].Radiology,2004,233(3):927-933.
  • 6Abada HT,Larchez C,Daoud B,et al.MDCT of the coronary arteries:feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose[J].AJR,2006,186(6):387-390.
  • 7Tariq AH,Shawn DT,Mani V,et al.Low radiation dose ECG-gated chest CT angiography on a 256-slice multidetector CT scanner[J].Int J Cardiovasc Imaging,2009,25(S2):267-278.
  • 8Wm GW,Mark EO,Matthew JW.Low-dose prospectively gated 256-slice coronary computed tomographic angiography[J].Int J Cardiovasc Imaging,2009,25(S2):217-230.
  • 9Ko SF,Hsieh MJ,Chen MC,et al.Effects of heart rate on motion artifacts of the aorta on non-ECG-assisted 0.5-sec thoracic MDCT.AJR Am J Roentgenol,2005,184(4):1225-1230.
  • 10Bax JJ,Schuijf JD.Which patients should be referred for noninvasive angiography with multi-slice CT? Int J Cardiol,2007,114(1):90-97.