摘要
本文应用CAESAR II对某润滑油加氢异构化装置预分馏塔抽真空系统进行管道应力分析,结果表明,由于蒸汽喷射器为不锈钢材质且操作温度较高,后冷器入口管嘴法兰压力等级低而受力较大等因素,抽真空系统管道柔性设计具有一定的研究价值。
Using CAESAR II,the pipe stress analysis of the vacuum system of pre-fractionation is taken.The steam ejector is made of stainless steel and has a high operating temperature.The inlet nozzle of the rear cooler has a large force and its flange pressure rating is low.The results show that the flexible design of the pipeline in the vacuum system has some research value.
作者
吴升元
Wu Shengyuan(SINOPEC,Guangzhou Engineering Co.,Ltd.,Guangzhou 510000,China)
出处
《山东化工》
CAS
2020年第9期148-150,共3页
Shandong Chemical Industry
关键词
分馏塔
蒸汽喷射器
应力分析
fractionation tower
steam ejector
stress analysis