摘要
在介绍干气密封控制系统的基础上,结合天然气增压站因干气密封放空管线憋压造成的压缩机联锁停车实例,分析了干气密封放空管线在运行当中存在的隐患,并提出了整改措施。
Based on the introduction of the control system of dry gas seal,combined with the example of compressor interlock shutdown caused by the pressure holding of dry gas seal vent pipeline in a natural gas booster station,this paper analyzes the hidden dangers existing in the operation of dry gas seal vent pipeline,and puts forward the rectification measures.
作者
苏炤兴
丁小川
刘华庆
Su Zhaoxing;Ding Xiaochuan;Liu Huaqing(Yulin to Jinan Natural Gas Pipeline Subsidiary of SINOPEC.,Jinan 250001;Jinan Municipal Engineering Quality Supervision Station.,Jinan 250001)
出处
《石化技术》
CAS
2020年第5期18-19,共2页
Petrochemical Industry Technology
关键词
天然气
离心压缩机
干气密封
放空
Natural gas
Centrifugal compressor
Dry gas seal
Vent