期刊文献+

格栅泄漏的分析与对策 被引量:1

Analysis and Counter Policy against Tray Leaking of Adsorbers
下载PDF
导出
摘要 本文主要从吸附塔格栅的结构来分析吸附塔床层压差上涨的原因,并根据可能的漏点,采取相应的对策,来减少或消除反冲洗的次数,为今后吸附塔的稳定运行提供长期的综合解决方案。 This article focuses on the internal structures to illustrate the possible reasons of pressure drop increase of Adsorber trays.Counter policies have been proposed upon the probable leaking spot,which provides the comprehensive technical solution for the Aromatics complex for long term stable operation.
作者 庄海阳 Zhuang Haiyang(PX Complex of Huizhou Refinery,CNOOC,Huizhou 516086,China)
出处 《广东化工》 CAS 2020年第12期174-174,161,共2页 Guangdong Chemical Industry
关键词 格栅 环形室 分配管 压差 tray annual chamber manifold pressure drop
  • 相关文献

参考文献2

二级参考文献5

  • 1李燕秋,白尔铮,段启伟.芳烃生产技术的新进展[J].石油化工,2005,34(4):309-315. 被引量:45
  • 2叶振华,宋清,朱建华.工业色谱基础理论和应用.第1版,1998:14:196-224.
  • 3Mirjana Minceva, Al'trio E. Rodrigues. Two-level optimization of an existing SMB for p-xylene separation [J]. Computers and Chemical Engineering, 2005, 29:2215-2228.
  • 4赵振国.吸附作用应用原理.第1版,2005:314-429.
  • 5马淑芬,杨春育,佟泽民,何晓明,朱建华.模拟移动床吸附分离技术[J].北京石油化工学院学报,2003,11(1):34-39. 被引量:8

共引文献8

同被引文献8

引证文献1

二级引证文献1

相关作者