摘要 The contradiction of variable step size least mean square(LMS)algorithm between fast convergence speed and small steady-state error has always existed.So,a new algorithm based on the combination of logarithmic and symbolic function and step size factor is proposed.It establishes a new updating method of step factor that is related to step factor and error signal.This work makes an analysis from 3 aspects:theoretical analysis,theoretical verification and specific experiments.The experimental results show that the proposed algorithm is superior to other variable step size algorithms in convergence speed and steady-state error.
作者 李相敏 Fang Yubin Zhu Xiaojin Huang Yonghui Zhou Yijia Li Xiangmin;Fang Yubin;Zhu Xiaojin;Huang Yonghui;Zhou Yijia(School of Mechatronics Engineering and Automation,Shanghai University,Shanghai 200240,P.R.China)
出处 《High Technology Letters》 EI CAS 2020年第2期178-187,共10页 高技术通讯(英文版)
基金 the National Natural Science Foundation of China(No.51575328,61503232).