期刊文献+

超声弹性成像对校正BI-RADS-US 3类及4类乳腺肿块的诊断价值 被引量:1

Value of BI-RADS-US rectified by ultrasound elastography in diagnosis of type 3 and type 4 breast lumps
下载PDF
导出
摘要 目的分析超声弹性成像对校正乳腺超声影像报告数据系统(Breast Imaging and Reporting System Ultrasound,BI-RADS-US)3类及4类乳腺肿块的诊断价值。方法对常规BI-RADS-US分类法诊断为3类及4类的乳腺肿块用超声弹性成像进行校正,以病理结果为金标准,对比分析校正前后的BI-RADS-US分类法对乳腺肿块良恶性的鉴别诊断效能。结果常规BI-RADS-US分类法诊断乳腺良恶性肿块的灵敏度、特异度、准确度分别为75.6%、88.1%、83.8%,受试者工作特征(ROC)曲线下面积为0.836。经超声弹性成像校正后BI-RADS-US分类法的诊断灵敏度、特异度、准确度分别为82.9%、93.1%、90.8%,ROC曲线下面积为0.918。校正前后ROC曲线下面积比较差异有统计学意义(P<0.05)。结论弹性成像有助于提高超声对BI-RADS-US 3类及4类乳腺肿块良恶性的鉴别诊断效能。 Objective To analyze the value of Breast Imaging and Reporting System Ultrasound(BI-RADS-US)rectified by ultrasound elastography in diagnosis of type 3 and type 4 breast lumps.Methods Breast lumps of type 3 and type 4 diagnosed by conventional BI-RADS-US classification were diagnosed by ultrasound elastography as rectification.With the pathological results as the gold standard,the efficacies of BI-RADS-US classification were compared and analyzed in differential diagnosis of benign and malignant breast tumors before and after rectification.Results The sensitivity,specificity and accuracy of the conventional BI-RADS-US classification were 75.6%,88.1%and 83.8%respectively in diagnosis of benign and malignant breast tumors,and the area under the receiver operating characteristic(ROC)curve was 0.836.The sensitivity,specificity and accuracy of the BI-RADS-US classification with ultrasound elastography rectification were 82.9%,93.1%and 90.8%respectively,and the area under ROC curve was 0.918.There were significant differences in the areas under ROC curve before and after rectification(P<0.05).Conclusion Elastography is conducive to improving the diagnostic efficacies of ultrasound in the differential diagnosis of benign and malignant breast tumors of BI-RADS-US type 3 and type 4.
作者 席剑雾 周翌炜 叶剑强 XI Jian-wu;ZHOU Yi-wei;YE Jian-qiang(Department of Medical Ultrasonics, Wuxi Huishan District People′s Hospital, Jiangsu 214187, China)
出处 《中国临床新医学》 2020年第6期599-602,共4页 CHINESE JOURNAL OF NEW CLINICAL MEDICINE
关键词 超声弹性成像 校正 乳腺肿块 乳腺超声影像报告数据系统 Ultrasound elastography Rectification Breast lumps Breast Imaging and Reporting System Ultrasound(BI-RADS-US)
  • 相关文献

参考文献4

二级参考文献26

  • 1李俊来,黄炎,王知力,万文博,苏莉,唐杰.乳腺实时剪切波弹性成像的组织定征研究[J].中华医学超声杂志(电子版),2011,8(4):812-819. 被引量:68
  • 2王启俊,祝伟星,邢秀梅.北京城区女性乳腺癌发病死亡和生存情况20年监测分析[J].中华肿瘤杂志,2006,28(3):208-210. 被引量:81
  • 3唐利立,廖妮,肖萤,廖锦堂,吴白云,毛杰,申郑堂,欧慧英,邬玉辉,海健,李燕.高频B超在中国妇女致密型乳腺的乳腺癌筛查中的应用[J].中国普通外科杂志,2006,15(10):732-735. 被引量:35
  • 4罗葆明,欧冰,智慧,曾婕,杨海云.改良超声弹性成像评分标准在乳腺肿块鉴别诊断中的价值[J].现代临床医学生物工程学杂志,2006,12(5):396-398. 被引量:372
  • 5American College of Radiology.Breast imaging reporting and data system (BI RADS),4th edn.American College of Radiology,2003,Reston.
  • 6American College of Radiology.Partial protocol contact acrin protocol development and regulatory compliance for a complete protocol..American College of Radiology,2004,Reston.
  • 7Ophir J,Céspedes I,Ponnekanti H,et al.Elastographya:a quantitative method for imaging the elasticity of biological tissues.J Ultrason Imaging,1991,13 (2):111-134.
  • 8Evans A,Whelehan P,Thomson K,et al.Differentiating benign from malignant solid breast masses:value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification.Br J Cancer,2012,107:224-229.
  • 9Sadigh G,Carlos RC,Neal CH,et al.Ultrasonographic differentiation of malignant from benign breast lesions:a meta-analytic comparison of elasticity and BIRADS scoring.Breast Cancer ResTreat,2012,133 (1):23-35.
  • 10陈圆圆,刘军杰,魏晏平,等.彩色多普勒血流显像与超声弹性成像联合诊断断BI-RADS 4类乳腺病变.中国医学影像杂志,2013,21 (5):332-335.

共引文献130

同被引文献14

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部