期刊文献+

加热器端差对机组热经济性的影响 被引量:3

Influence of Terminal Temperature Difference on Thermal Economy of Generating Units
下载PDF
导出
摘要 为降低机组发电成本,实现提质增效目标,针对机组各加热器类型,计算分析得出加热器端差对机组热经济性影响特性,并通过实验获得控制发电成本手段。结果显示,端差对机组抽汽等效焓降、汽耗率、标准煤耗率的影响随抽汽级数和负荷的变化产生不同影响。在实际运行中,负荷越高能耗敏度越小。但由于负荷越高,端差越大,导致高负荷下端差引起的发电成本增加值越大。试验发现,通过调节高压加热器液位可减小端差,从而降低发电成本。 To reduce the power generating cost and achieve the goal of quality improvement and efficiency increase,the influence characteristics of the heater terminal temperature difference on the thermal economy of the unit are calculated and analyzed according to the heater type of the unit,and the means for generation cost control are obtained through the experiment.The results show that the influence of terminal temperature difference on the equivalent enthalpy drop,vapor consumption rate and standard coal consumption rate of the unit varies with the extraction steam numbers and load.In actual operation,the load varies inversely with energy consumption sensitivity.However,the load increases with terminal temperature difference,leading to an added value increase of power generation cost due to terminal temperature difference under high load.It is found by the test that the level regulation of the high-pressure heater can reduce the terminal temperature difference and can thereby the power generation cost.
作者 朱国栋 郑坚刚 李朋 张敬坤 俞亚勇 王超 刘友彪 张炜 ZHU Guodong;ZHENG Jiangang;LI Peng;ZHANG Jingkun;YU Yayong;WANG Chao;LIU Youbiao;ZHANG Wei(Changxing Power Plant,Huaneng Power International,Inc.,Changxing Zhejiang 313100,China)
出处 《浙江电力》 2020年第6期74-80,共7页 Zhejiang Electric Power
关键词 端差 等效焓降 标准煤耗率 发电成本 terminal temperature difference equivalent enthalpy drop standard coal consumption rate generation cost
  • 相关文献

参考文献10

二级参考文献52

共引文献117

同被引文献24

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部