期刊文献+

电感耦合等离子体发射光谱法测定水溶肥料中五氧化二磷的含量 被引量:1

Determination of P2O5 in water soluble fertilizer by inductively coupled plasma atomic emission spectrometry
下载PDF
导出
摘要 采用电感耦合等离子体发射光谱法,实现了对水溶肥料产品中五氧化二磷含量的直接测定,避免了水解不完全导致的结果偏低等问题。该方法五氧化二磷浓度在0.00~200.0 mg/L范围内具有良好的线性关系(r^2=0.9998),相对标准偏差(RSD)在0.25%~0.47%之间,加标回收率在97.92%~102.0%,检出限为0.0028%。同时,与磷钼酸喹啉重量法检测结果进行比较,结果相吻合,能够满足样品中五氧化二磷含量的分析检测要求。 The inductively coupled plasma atomic emission spectrometry method has been used to quantitatively detect P2O5 content in water soluble fertilizer by screening suitable analytical lines,it avoids the problem of low results caused by incomplete hydrolysis.The P2O5 concentrations have a good linear relationship(r^2=0.9998)in the range of 0.00~200.0 mg/L,the relative standard deviation(RSD)is 0.25%~0.47%,and the recoveries are 97.92%~102.0%.The limit of detection is 0.0028%.Meanwhile,the results are compared with those of quinoline phosphomolybdate gravimetric method,which shows this method can meet the requirements of real sample analysis.
作者 姚莎 张智杰 孙丽丽 陈萌 YAO Sha;ZHANG Zhi-jie;SUN Li-li;CHEN Meng(Yunnan Chemical Research Institute,Yunnan Kunming 650228;Yunnan Yuntianhua Co.,Ltd.,Yunnan Kunming 650228;Yunnan Chemical Product Quality Supervision and Inspection Station,Yunnan Kunming 650228)
出处 《中国土壤与肥料》 CAS CSCD 北大核心 2020年第3期220-223,共4页 Soil and Fertilizer Sciences in China
关键词 电感耦合等离子体发射光谱法 水溶肥料 五氧化二磷 inductively coupled plasma atomic emission spectrometry water soluble fertilizer P2O5