期刊文献+

变频牵引电机定子绕组绝缘老化特性研究 被引量:5

Research on Stator Winding Insulation Deterioration for Inverter-Fed Traction Motors
下载PDF
导出
摘要 对比测量了不同运行年限的变频牵引电机的定子绕组绝缘诊断参数,包括绝缘电阻、介质损耗因数、局部放电起始电压(PDIV)、剩余击穿电压等特征参数,以及沿绕组不同部位的绝缘材料取样进行了热失重分析(TGA)来研究绝缘老化特征。介电性能测量结果表明,与新电机相比,运行后定子绕组的绝缘介电性能有不同程度的下降,出槽口附近绝缘的老化程度高于槽内。TGA分析结果表明,使用了长达10年的牵引电机定子绕组绝缘性能略有下降,且线圈下层边的绝缘老化比上层边明显。 The characteristic parameters of the stator winding insulations in the inverter-fed traction motors with various service years,including the insulation resistance,dissipation factor,partial discharge inception voltage(PDIV)and residual breakdown voltage,are measured sequentially to analyze the insulation deterioration.The insulation materials from different sites of the insulation along the windings are sampled and analyzed with thermogravimetric analysis(TGA).The measured dielectric results show that the characteristic parameters from the stator windings decrease slightly in comparison with those of new motors.The aging degree of the insulation near the outlet slot is higher than that in the slot.Besides,the TGA results from the sampled insulation materials indicate that the stator winding insulation in the inverter-fed traction motor with a service period up to ten years shows slight deterioration.Generally,more serious deterioration in the insulation tends to appear at the bottom side of the motor coils.
作者 雷平振 樊洁心 刘冠芳 李斌寅 牛玉龙 LEI Pingzhen;FAN Jiexin;LIU Guanfang;LI Binyin;NIU Yulong(CRRC Yongji Electric Co.,Ltd.,Xi’an 710018,China)
出处 《电机与控制应用》 2020年第6期33-37,共5页 Electric machines & control application
关键词 变频牵引电机 定子绝缘 绝缘老化 绝缘试验 inverter-fed traction motor stator insulation insulation deterioration insulation test
  • 相关文献

参考文献3

二级参考文献31

  • 1欧阳本红,刘丽兵,江裕熬,高乃奎.发电机定子绝缘剩余寿命评估参量的选择[J].高电压技术,2005,31(1):30-32. 被引量:9
  • 2李鸿岩,王峰,郭磊,刘斌,陈寿田.变频电机的匝间绝缘电老化机理[J].绝缘材料,2005,38(2):57-60. 被引量:23
  • 3郑飞虎,张冶文,肖春.聚合物电介质的击穿与空间电荷的关系[J].材料科学与工程学报,2006,24(2):316-320. 被引量:51
  • 4DL/T596-1996 电力设备预防性规程[S],1996.
  • 5JB/T56082-1996 汽轮发电机产品质量分等[S],1996.
  • 6YIN Wei-jun. Failure mechanism of Winding Insulations in Inverter-fed Motors [J]. IEEE Electrical Insulation Magazine, 1997, 13(6): 18-23.
  • 7BONNETT A H. Analysis of the Impact of Pulse-width Modulated Inverter Voltage Waveforms on AC Induction Motors [J]. IEEE Trans. on Industry Applications, 1996, 32 (2): 386-392.
  • 8MOHSEN F, HOSSEIN B, ERNST G, et al. Partial Discharge and Dissipation Factor Behavior of Model Insulating Systems for High Voltage Rotating Machines under Different Stresses [J]. IEEE Electrical Insulation Magazine, 2005, 12 (5): 5-19.
  • 9BELLOMO J P, CASTELAN P, LEBEY T. The Effect of Pulsed Voltages on Dielectric Material Properties [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 1999, 6 (1): 20-26.
  • 10Kaufhold M, Schafer K, Bauer K, et al. Interface Phenomenain Stator Winding Insulation-challenges in Design, Diagnosis,and Service Experience[J]. IEEE Electrical InsulationMagazine,2002,18(2):27-36.