摘要 通过变压器油色谱分析可以初步推断变压器内部缺陷的性质,再结合电气试验等手段进行综合分析,可提高变压器内部缺陷诊断的准确性。介绍了一起220 kV变压器总烃超标案例,应用三比值法判断内部存在高温过热,综合停电诊断试验数据,诊断变压器内部存在磁回路裸金属发热问题。检修人员对变压器进行内检,发现低压绕组串联的电抗器固定拉杆螺栓螺母处存在轻微烧伤,进一步拆解发现平垫片与螺母烧蚀明显,结构破损。更换烧蚀零件后,缺陷消除。缺陷分析诊断过程对此类变压器缺陷的诊断分析具有一定参考意义。 The transformer oil chromatographic analysis can be used to preliminarily infer the nature of the internal defects of the transformer.Combining electrical tests and other means for comprehensive analysis,the accuracy of the internal fault diagnosis of the transformer can be improved.A 220 kV transformer total hydrocarbon excess case was introduced.The three ratio method was used to judge the existence of high temperature overheating.Comprehensive power failure diagnostic test data was used to diagnose the existence of bare metal heating in the magnetic circuit of the transformer.The internal inspection of the transformer by the maintenance staff found that there was a slight burn at the bolts and nuts of the fixed rods of the reactor connected in series in the low-voltage winding.Further disassembly revealed that the flat gasket and nut were ablated obviously and the structure was damaged.Defects were eliminated after replacement of ablative parts.The process of defect diagosis and analysis has certain reference significance for the diagnosis and analysis of such transformer defects.
作者 王政 郭峰 杨锟 赵恒伟 马霄霖 WANG Zheng;GUO Feng;YANG Kun;ZHAO Hengwei;MA Xiaolin(State Grid Binzhou Power Supply Company,Binzhou 256600,China)
出处 《山东电力技术》 2020年第6期52-55,58,共5页 Shandong Electric Power
关键词 变压器 绝缘油 总烃 缺陷诊断 transformer insulating oil total hydrocarbons defect diagnosis
  • 相关文献

参考文献6

二级参考文献15

  • 1GB/T7252-2001.变压器油中溶解气体分析和判断导则[S].[S].,..
  • 2Barry, Finlay. Oil-filled electrical plant condition assessment interpretation of dissolved gas analysis[R]. Newcastle, Australia: Advanced Technology Center, Pacific Power International, 1995.
  • 3Lin Weisong, Hung Chinpao, Wang Manghui. CMAC-based fault diagnosis of power transformer[J]. IEEE trans on Power Delivery, 2002, 16(2) : 986-991.
  • 4Wang Manghui. A novel extension method for transformer fault diagnosis[J]. IEEE trans on Power Delivery, 2003, 18(1): 164-169.
  • 5DL/T596-1996.电力设备预防性试验规程[S].[S].,..
  • 6操敦奎.变压器油中气体分析诊断与故障检查[M].北京:中国电力出版社,2006.
  • 7GB/T 7252-2001 变压器油中溶解气体分析判断导则[S],2001.
  • 8李逊,徐浩俊.一起变压器油色谱异常的分析及处理[J].浙江电力,2010,29(5):28-30. 被引量:4
  • 9张冠军,钱政,严璋.DGA技术在电力变压器绝缘故障诊断中的应用与进展[J].变压器,1999,36(1):30-34. 被引量:37
  • 10王佩璋,叶涟远,何志武.浅议变压器过热型故障部位的判定[J].中国电力,2000,33(1):86-89. 被引量:7

共引文献59

同被引文献108

引证文献15

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部