期刊文献+

枕头坝一级水电站技术供水系统压力异常分析与改进措施 被引量:4

Analysis and Treatment of Abnormal Pressure in Technical Water Supply System in Zhentouba I Hydropower Station
下载PDF
导出
摘要 枕头坝一级水电站汛期机组技术供水常出现压力异常现象,滤水器普遍存在频繁堵塞问题,对机组安全稳定运行造成了极大困扰。通过对故障成因分析,从机组技术供水系统的工程设计、安装、运行、检修维护诸方面对其优化、改造、提高供水的可靠性进行了有益的探索。 In Zhentouba I Hydropower Station,clogging of the water filters and abnormal pressure of the technical water supply system are frequently observed,which cause great trouble to the safe and stable operation of the units.Possible causes of the issue are analyzed.Then,renovation measures to improve the reliability of the water supply are proposed to the technical water supply system from the aspects of engineering design,installation,operation and maintenance.
作者 蒋巍巍 唐义超 朱昌鑫 JIANG Weiwei;TANG Yichao;ZHU Changxin(China Guodian Dadu River Maintenance and Installation Co., Ltd., Leshan 614900, China)
出处 《水电与新能源》 2020年第6期71-74,共4页 Hydropower and New Energy
关键词 枕头坝 技术供水系统 蜗壳取水 拦污栅 Zhentouba Hydropower Station technical water supply system water intake from volute trash rack