期刊文献+

Refractive index and temperature sensor based on cleaved taper and spherical structure 被引量:2

原文传递
导出
摘要 An in-line Mach-Zehnder interferometer(MZI) for simultaneous measurement of temperature and refractive index(RI) is proposed and demonstrated. The sensor is composed of cleaved taper, single-mode fiber(SMF) and spherical structure. Using precision device to measure the position of waist, the cleaved taper structure is obtained by cutting the taper structure. The sensitivities of the temperature are 0.052 nm/℃ and 0.037 nm/℃ in the temperature range of 25-70 ℃, respectively. The RI sensitivities are-56.59 nm/RIU and-43.53 nm/RIU in the RI range of 1.335-1.38, respectively. This sensor has many advantages such as compact structure and good stability.
作者 仲怡美 童峥嵘 宋殿友 张卫华 秦娟 高文林 ZHONG Yi-mei;TONG Zheng-rong;SONG Dian-you;ZHANG Wei-hua;QIN Juan;GAO Wen-lin(Tianjin Key Laboratory of Film Electronic and Communication Devices,Engineering Research Center of Optoelectronic Devices and Communication Technology,Ministry of Education,School of Electrical and Electronic Engineering,Tianjin University of Technology,Tianjin 300384,China)
出处 《Optoelectronics Letters》 EI 2020年第3期171-175,共5页 光电子快报(英文版)
基金 the National Youth Natural Science Foundation of China(No.11704283) the Natural Science Foundation of Tianjin(No.18JCYBJC86300) the Tianjin Municipal Education Commission Scientific Research Project(No.2018KJ132).
  • 相关文献

同被引文献3

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部