AIDR3D对胸部低剂量CT扫描图像质量及辐射剂量的影响 被引量:4

下载PDF
导出
摘要 目的探讨低剂量自适应迭代重建技术(AIDR3D)对胸部低剂量CT扫描图像质量及辐射剂量的影响。方法回顾性分析2018年1月至2019年2月106例在该院门诊部行胸部CT检查患者的临床资料,依据检查方法不同分为对照组(常规低剂量胸部CT检查,n=46)和试验组(在对照组基础上联合AIDR3D进行检查,n=60),比较两组图像质量(噪声、伪影、细小结构显示、胸部病变显示评分)、辐射剂量[容积CT剂量指数(CTDIvol),剂量长度乘积(DLP)]。结果试验组噪声、伪影、细小结构显示、胸部病变显示评分明显低于对照组,差异有统计学意义(P<0.05);试验组CTDIvol、DLP明显小于对照组,差异有统计学意义(P<0.05)。结论将AIDR3D应用于胸部低剂量CT扫描中不仅可提高图像质量且能有效降低辐射剂量,有助于早期发现和诊断胸部疾病。
出处 《检验医学与临床》 CAS 2020年第13期1917-1919,共3页 Laboratory Medicine and Clinic
  • 相关文献

参考文献10

二级参考文献46

  • 1Kwon JK,Chang IH,Moon YT,et al.Usefulness of lowdose nonenhanced computed tomography with iterative reconstruction for evaluation of urolithiasis:diagnostic performance and agreement between the urologist and the radiologist.Urology,2015,85(3):531-538.
  • 2Gervaise A,Naulet P,Beuret F,et al.Low-dose CT with automatic tube current modulation,adaptive statistical iterative reconstruction,and low tube voltage for the diagnosis of renal colic:impact of body mass index.Am J Roentgenol,2014,202(3):553-560.
  • 3Rampado O,Marchisio F,Izzo A,et al.Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom.Eur J Radiol,2009,72(1):181-187.
  • 4Flicek KT,Hara AK,Silva AC,et al.Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction:a pilot study.Am J Roentgenol,2010,195(1):126-131.
  • 5Kulkarni NM,Uppot RN,Eisner BH,et al.Radiation dose reduction at multidetector CT with adaptive statistical iterative reconstruction for evaluation of urolithiasis:how low can we go?Radiology,2012,265(1):158-166.
  • 6Valentin J.Managing patient dose in multi-detector computed tomography(MDCT).ICRP Publication 102.Ann ICRP,2007,37(1):1-79.
  • 7Li X,Yu Y,Liu B,et al.Radiation dose reduction at multidetector CT.Radiology,2013,268(3):925-926.
  • 8Thibault JB,Sauer KD,Bouman CA,et al.A three-dimensional statistical approach to improved image quality for multislice helical CT.Med Phys,2007,34(11):4526-4544.
  • 9Mclaughlin PD,Murphy KP,Hayes SA,et al.Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic;impact of iterative reconstruction on image quality and diagnostic performance.Insights Imaging,2014,5(2):217-230.
  • 10张祺丰,彭芸,李剑颖,刘玥,曾津津.64排螺旋CT自动管电流调节技术降低儿童胸部扫描剂量的应用研究[J].中国医学影像技术,2009,25(9):1591-1594. 被引量:42