摘要
地铁换乘站周边建筑较多,基坑开挖较深,极易影响周边建筑地基稳定性,造成不均匀沉降,以倪家桥站为例,对车站周边建筑注浆加固技术进行研究,确定了注浆加固所需材料和各项工艺参数,为类似工程提供参考。
There are many buildings around the subway transfer station,the excavation of the foundation pit is deep,which is easy to affect the stability of the surrounding building foundation,resulting in uneven settlement.Taking Nijiaqiao station as an example,this paper studies the grouting reinforcement technology of the surrounding buildings of the station,determines the materials and various process parameters required for grouting reinforcement,and provides reference for similar projects.
作者
周兴荣
Zhou Xingrong(Southwest Engineering Headquarters of Tonghao Construction Group Co.,Ltd.,Chengdu 610041,China)
出处
《山西建筑》
2020年第14期77-79,共3页
Shanxi Architecture
关键词
地铁换乘站
周边建筑
注浆加固
subway transfer station
surrounding building
grouting reinforcement