摘要 随着国家对锅炉大气污染物排放标准的逐步提高,对燃煤锅炉实施了脱硝改造,但低温省煤器频繁出现泄漏。通过对泄漏原因的分析,对低温省煤器和吹灰系统实施了技术改造,低温省煤器的泄漏次数明显减少,在排放烟气满足国家对锅炉大气污染物排放标准要求的同时,也提高了锅炉热效率。 With the gradual tightening of national emission standards for air pollutants from boilers,the denitrification renovation has been implemented on coal-fired boiler,but low-temperature economizer frequently leaks.Through analysis of the causes of leakage,the low-temperature economizer and sootblowing system have been technically reformed,which has significantly reduced the number of low-temperature economizer leakages.While the flue gas emission meets the requirements of national standard for boiler air pollutants emission,the boiler thermal efficiency has also increased.
作者 吴玲燕 WU Lingyan(Sinopec Yangzi Petrochemical Co.,Ltd.,Nanjing,Jiangsu 210048,China)
出处 《肥料与健康》 CAS 2020年第3期46-49,共4页 Fertilizer & Health
关键词 烟气脱硝 燃煤锅炉 低温省煤器 排放烟气 热效率 技术改造 flue gas denitrification coal-fired boiler low-temperature economizer flue gas emission thermal efficiency technical transformation