摘要
针对地铁直流牵引供电系统中杂散电流、轨电位对站台门设计方案的影响,对站台门绝缘问题进行了分析。在保证地铁安全运营及人身安全的前提下,提出了解决站台门绝缘问题的相关措施,以消除杂散电流腐蚀及站台门金属构件打火、燃烧的隐患。
In view of the influence of stray current and rail potential on the design scheme of platform door in metro DC traction power supply system,the insulation problem of platform door is analyzed.On the premise of ensuring the safe operation and personal safety of subway,the paper puts forward the relevant measures to solve the insulation problem of platform door,so as to eliminate the hidden dangers of stray current corrosion and the ignition and combustion of platform door metal components.
作者
王哲
WANG Zhe(CREEC East China Survey and Design Co.Ltd.,Hangzhou 310004,China)
出处
《工程建设与设计》
2020年第13期84-86,共3页
Construction & Design for Engineering
关键词
杂散电流
钢轨电位
等电位联结
放电打火
绝缘安装
stray current
rail potential
equipotential bonding
spark discharge
insulation installation