摘要
VOCs作为环保管控防制的重点,国内外出台了多个法规、标准对法兰联接的泄漏量(泄漏率)做了具体的规定。但不同法规、标准的检漏方式及泄漏率单位各不相同,在实际执行过程中有一定的困惑。该文针对泄漏测试方法以及泄漏率单位间的换算比对进行了探讨,并对日常操作提出了建议。
VOCs control is critical for the environmental protection.Many law,regulations and standards are issued worldwide.The tightness is specified.Due to the different testing method and related leakage unit,people are confused to follow.This paper compares the leakage testing method and unit,and submit some conclusions.
作者
林剑红
武跃维
徐丹丹
柴立民
LIN Jian-hong;WU Yue-wei;XU Dan-dan;CHAI Li-min(Ningbo IDT SINYUAN Sealing Technology Co.,Ltd.,Ningbo 315021,China)
出处
《液压气动与密封》
2020年第7期42-44,49,共4页
Hydraulics Pneumatics & Seals
关键词
VOCS
检漏方法
泄漏率
比对
VOCs
leakage testing method
leakage rate unit
comparison