摘要
介绍了氟利昂制冷剂的小型压缩制冷设备的基本组成、工作原理,给出制冷不良故障诊断网络节点树,针对制冷不良故障原因进行了诊断。
This paper introduces the basic composition and working principle of a small-scale Freon refrigerant compression refrigeration equipment,gives a network node tree for poor cooling fault diagnosis,and diagnoses the causes of poor cooling faults.
作者
牛洪兵
鲁春梅
NIU Hongbing;LU Chunmei(Nanjing Changjiang Electronics Group Co.,Ltd.,Nanjing 210038,China)
出处
《机械工程师》
2020年第7期141-142,145,共3页
Mechanical Engineer
关键词
压缩制冷
压缩
冷凝
膨胀
蒸发
制冷不良
compression refrigeration
compression
condensation
expansion
evaporation
poor refrigeration