期刊文献+

定量超声骨密度测量系统中系统延迟时间的测量研究

Study on the measurement of system delay time in quantitative ultrasound bone mineral density measurement system
下载PDF
导出
摘要 骨超声传导速度是定量超声骨密度测量系统的主要参数之一,主要反映骨骼的矿物质密度。精密测量骨骼的超声传导速度,就必须测得系统延迟时间。为了探索高精度的测量方法,得到准确的系统延迟时间,本研究提出了最小二乘线性回归拟合测量法,并将其测量效果与传统直接法进行对比。实验证明,该方法能避免直接法测量中的系统误差,得到准确的系统延迟时间。在特定实验条件下,可明显减小超声传导速度的测量误差。 The speed of sound(SOS)is one of the main parameters in diagnosing osteoporosis using quantitative ultrasound device.It′s necessary to measure the delay time of the quantitative ultrasound system to get the SOS of bones.In order to explore high precision measurement method and obtain accurate system delay time,we proposed a measuring method of linear fitting based on least square method and compared it with traditional direct method.The experiments show that linear fitting method can avoid systematic error to get accurate value of delay time and greatly reduce measuring error of the speed of sound.
作者 张晓斌 冯帅 郑驰超 彭虎 ZHANG Xiaobin;FENG Shuai;ZHENG Chichao;PENG Hu(The First Affiliated Hospital of Anhui Medical University, Hefei 230022,China;Hefei University of Technology, Hefei 230000)
出处 《生物医学工程研究》 2020年第2期171-175,共5页 Journal Of Biomedical Engineering Research
关键词 骨超声传导速度 系统延迟时间 骨矿密度 直接法 线性拟合法 Speed of sound System delay time Bone mineral density Direct method Linear fitting method
  • 相关文献

参考文献13

二级参考文献103

共引文献2372

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部