摘要 由于DPZ1综合硬件控制器工作性能的不稳定,造成综合气象观测业务软件ISOS无法正常采集气象观测数据,影响台站观测数据的上传。经过台站业务人员与装备保障人员反复进行观测试验,确定故障由DPZ1综合硬件控制器内核版本过低导致。更换相关设备后,故障排除,解决了长时间困扰台站观测业务人员的问题。 Due to the instability of the work performance of DPZ1 integrated hardware controller,the integrated meteorological observation service software ISOS cannot collect meteorological observation data normally,which will affect the uploading of the observation data of the station.Through the joint efforts of station operators and equipment support personnel,repeated observation tests are conducted.The faults are caused because of the poor performance of the built-in network card of the DPZ1 integrated hardware controller,which has resulted in the unstable performance of the integrated hardware controller.After the replacement of the relevant equipment,the problems that had been troubling the station observation personnel for a long time are solved by troubleshooting.