期刊文献+

电镀工业园区污水处理厂的设计与运行 被引量:1

Design and operation of sewage treatment plant in electroplating industrial park
下载PDF
导出
摘要 采用“预处理+pH调节+Fenton+脱气+混凝沉淀+A2O+混凝沉淀+转盘滤池+臭氧催化氧化+UF+RO”的工艺对电镀废水进行回用处理。出水满足《城市污水再生利用工业用水水质》(GB/T 19923—2005)回用标准,可用于清洗。浓水采用“pH调节+Fenton+脱气+混凝沉淀+活性炭吸附+离子交换”工艺进行深度处理。出水满足《电镀污染物排放标准》(GB 21900—2008)表2标准,排入长江。 Electroplating wastewater is treated and reused by the process of“pretreatment+pH adjustment+Fenton+degassing+coagulation and sedimentation+A2O+coagulation and sedimentation+rotary filter+ozone catalytic oxida-tion+UF+RO”.The effluent meets the Reuse of Urban Recycling Water-Water Quality Standard for Industrial Uses(GB/T 19923—2005)and is used for factory cleaning.The concentrated water is treated in-depth by the process of pH adjustment+Fenton+degassing+coagulation and sedimentation+activated carbon adsorption+ion exchange.The effluent meets the standard in Table 2 of Emission Standard of Pollutants for Electroplating(GB 21900—2008)and is discharged into the Yangtze River.
作者 丁聪 李少华 刘锋 祝妍华 赵丹 Ding Cong;Li Shaohua;Liu Feng;Zhu Yanhua;Zhao Dan(School of Environmental Science and Engineering,Suzhou University of Science and Technology,Suzhou 215009,China;National Urban Wastewater Utilization Technology National Place JointEngineering Laboratory,Suzhou 215009,China;Environmental Inspection Team of SuzhouHuqiu District,Suzhou 215009,China)
出处 《工业水处理》 CAS CSCD 北大核心 2020年第7期107-111,共5页 Industrial Water Treatment
基金 苏州区域水质提升与水生态安全保障技术及综合示范项目(2017ZX07205)。
关键词 电镀工业园区 脱脂废水 回用 浓水 FENTON electroplating industrial park degreasing wastewater reuse concentrated water Fenton
  • 相关文献

参考文献7

二级参考文献42

共引文献53

同被引文献20

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部