摘要 锁铆或自攻螺钉连接的冷弯薄壁型钢组合墙在低周往复加载试验中,滞回曲线“捏拢”现象较为严重、耗能能力较差.为减轻地震作用下冷弯薄壁型钢组合墙的破坏,提高结构体系的耗能能力,提出了一种带有铅阻尼器的冷弯薄壁型钢组合墙结构体系,并基于冷弯薄壁型钢组合墙的角部连接方式、面板铆钉间距及种类3种变量对其进行抗震性能试验研究.试验结果表明:加入铅阻尼器后,基于锁铆或自攻螺钉连接的冷弯薄壁型钢组合墙结构体系在低周往复荷载作用下,变形能力和耗能能力均有大幅度提升,刚度退化趋于平缓,损伤指数有较明显的降低,破坏形态也得到优化,但屈服荷载及峰值荷载略有降低;其次减小铆钉间距后,组合墙的屈服荷载、峰值荷载、峰值位移、抗剪强度得到一定程度的提高,但能量耗散系数差别不大;同时基于锁铆连接的冷弯薄壁型钢组合墙的屈服位移、屈服荷载、峰值位移、峰值荷载也明显高于基于自攻螺钉连接的冷弯薄壁型钢组合墙,延性及能量耗散系数相差不大. In the low-cycle reciprocating loading test of cold-formed thin-walled steel composite wall connected with rivet locking or self-tapping screw,the phenomenon of“pinching”of hysteresis curve is serious and the energy dissipation capacity is poor.To reduce the damage of cold-formed thin-wall steel composite wall under earthquake and improve the energy dissipation capacity of the structure,a cold-formed thin-wall steel composite wall structure system with lead damper was proposed,and seismic performance experimental study was conducted based on three variables,i.e.,cold-formed thin-walled steel composite wall corner connection mode,panel rivet spacing,and type.Results show that with the addition of the lead damper,the deformation capacity and energy dissipation capacity of the cold-formed thin-walled steel composite wall structure system based on rivet locking or self-tapping screw connection were significantly improved under the low-cycle reciprocating loading.The stiffness degradation tended to be gentle,the injury index was significantly decreased,and the failure pattern was optimized,while the yield load and peak load were slightly reduced.Then,with the rivet spacing reduced,the yield load,peak load,peak displacement,and shear strength of the composite wall were improved to some extent,but the energy dissipation coefficient had little difference.Meanwhile,the yield displacement,yield load,peak displacement,and peak load of the cold-formed thin-walled steel composite wall based on rivet connection were significantly higher than those of the cold-formed thin-walled steel composite wall based on self-tapping screw connection,but the ductility and energy dissipation coefficient of the walls were similar.
作者 闫维明 王曼 张文莹 YAN Weiming;WANG Man;ZHANG Wenying(Beijing Key Lab of Earthquake Engineering and Structural Retrofit(Beijing University of Technology),Beijing 100124,China)
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2020年第8期10-19,共10页 Journal of Harbin Institute of Technology
基金 国家自然科学基金(51678008)。
关键词 冷弯薄壁型钢 组合墙体 铅阻尼器 抗震性能 试验研究 cold-formed thin-walled steel composite wall lead damper seismic performance experimental study
  • 相关文献

参考文献10

二级参考文献54

  • 1何一民,史万春.关于发展新型轻钢结构建筑的建议[J].钢结构,1996,11(3):29-33. 被引量:8
  • 2弓晓芸.轻型钢结构建筑体系的发展及展望[J].工业建筑,1995,25(7):18-24. 被引量:15
  • 3周绪红,石宇,周天华,刘永健,周期石,狄谨,卢林枫.低层冷弯薄壁型钢结构住宅体系[J].建筑科学与工程学报,2005,22(2):1-14. 被引量:132
  • 4周绪红,石宇,周天华,狄谨.冷弯薄壁型钢结构住宅组合墙体受剪性能研究[J].建筑结构学报,2006,27(3):42-47. 被引量:57
  • 5.JGJ101-96建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997..
  • 6AISI RG-9804 Shear wall design guide [ S ]. Washington:American Iron and Steel Institute, 1995.
  • 7Serrette R, Ogunfunmi K. Shear resistance of gypsumsheathed light gauge steel stud walls [ J ]. Journal of Structural Engineering, 1996,122 ( 4 ) : 383-389.
  • 8Serrette R, Encalada J, Juadines M, et al. Static racking behavior of plywood, OSB, gypsum, and fiberboard walls with metal framing[ J]. Journal of Structural Engineering, 1997, 123(8) : 1079-1086.
  • 9Serrette R, Lam I, Qi H. Cold-formed steel frame shear walls utilizing structural adhesives [ J ]. Journal of Structural Engineering,2006,132 (4) : 591-599.
  • 10Tian Y S, Wang J, Lu T J, et al. An experimental study on the axial behavior of cold-formed steel wall studs and panels [J] . Thin-Walled Structures ,2004,42(4) :557-573.

共引文献175

同被引文献21

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部