摘要
阀控式铅酸蓄电池在使用过程中判断其使用寿命最直观的方式为检测电池容量,而对于运行中的蓄电池,电池内阻是一个可以在不影响蓄电池运行状态的情况下,较为准确反映蓄电池性能的方法。文章详细探讨了电池容量检测和电池内阻检测两种方法,并对其进行分析比较,以供参考。
The most intuitive way to judge the service life of valve regulated lead acid battery is to detect the capacity of battery.For the battery in operation,the internal resistance of battery is a more accurate way to reflect the performance of battery without affecting the operation state of battery.This paper discusses two methods of battery capacity detection and battery internal resistance detection in detail,and analyzes and compares them for reference.
作者
顾振洋
GU Zhen-yang(Air Traffic Administration of Southwest China Civil Aviation,Chengdu 610000,China)
出处
《通信电源技术》
2020年第9期251-253,共3页
Telecom Power Technology
关键词
阀控式铅酸蓄电池
容量测试
直流放电法
valve regulated lead acid battery
capacity test
DC discharge method