摘要
洁净室理论计算公式复杂,参数较多,容易混淆,为理顺各参数关系,明确了解各参数对于洁净风量的影响,文章通过具体算例,将复杂的公式计算拆解、剖析、简单化,方便工程师从设计角度,更好地理解其相关的各个参数,夯实理论基础,提升技术实力。
The theoretical calculation formula of clean room is complex,there are many parameters,and it is easy to be confused.In order to straighten out the relationship of each parameter and clearly understand the influence of each parameter on clean air volume,this paper disassembles,analyzes and simplifies the complex formula through specific examples.It is convenient for engineers to better understand the relevant parameters from the design point of view,lay the theoretical foundation and enhance the technical strength.
出处
《科技创新与应用》
2020年第22期56-57,61,共3页
Technology Innovation and Application
关键词
非单向流
洁净风量
理论计算
参数分析
non-unidirectional flow
clean air volume
theoretical calculation
parameter analysis