摘要 目的研制一种人血清淀粉样蛋白A(SAA)荧光定量免疫层析检测试剂盒,并对其性能进行初步评价。方法建立了一种基于时间分辨荧光微球的荧光免疫层析检测试剂盒(以下简称自制试剂盒)用于人SAA的定量检测,通过测试空白限、精密度、稳定性、与对比试剂盒的符合率,评价其性能。结果自制试剂盒的空白限为0.49 mg/L,批内变异系数小于15%,在热稳定性测试中表现出较好的稳定性,与西门子人SAA试剂盒具有良好相关性(R^2=0.9605)。结论自制的人SAA荧光定量免疫层析试剂盒可适用于SAA的临床检测。 Objective To develop a fluorescence immunochromatography assay kit for detection of human serum amyloid A(SAA)and to preliminarily evaluate its performance.Methods The fluorescence immunochromatography assay kit based on time-resolved fluorescent microspheres(hereinafter referred to as self-made kit)was established for the quantitative detection of human SAA.Its performance was evaluated by testing limit of blank,precision,stability and coincidence rate with the comparison kit.Results The limit of blank of the self-made kit was 0.49 mg/L,and the coefficient of variation within the batch was less than 15%.It showed good stability in the thermal stability test and had good correlation with the Siemens SAA kit(R 2=0.9605).Conclusion The self-made kit of fluorescence quantitative immunochromatography for human SAA can be used for clinical detection of SAA.
作者 吴萌 魏治静 WU Meng;WEI Zhijing(Cell Biochemical Chamber,Biology Institute,Hebei Academy of Sciences,Shijiazhuang,Hebei 050081,China)
出处 《现代医药卫生》 2020年第14期2170-2173,共4页 Journal of Modern Medicine & Health
关键词 人血清淀粉样蛋白A 时间分辨荧光微球 免疫层析 定量检测 急性期蛋白 Human serum amyloid A Time-resolved fluorescent microsphere Immunochromatography Quantitative test Actute-phase protein
  • 相关文献

参考文献11

二级参考文献139

  • 1陈绍森,陈飞鹏,陈晓军.阻塞性睡眠呼吸暂停患者血清淀粉样蛋白A水平研究[J].南方医科大学学报,2009,29(8):1599-1601. 被引量:2
  • 2曹丹如,张锦锋,刘德琮,朱晴晖,陶义训.快速检测尿微量白蛋白的半定量金免疫渗滤法的研究[J].检验医学,2004,19(5):429-431. 被引量:6
  • 3游冬青,陈杞.镧系离子时间分辨荧光检测法在核酸分析技术中的应用[J].光电子技术与信息,1994,7(5):41-44. 被引量:5
  • 4田小侠,刘乃政,朱桂峰,司磊.急性冠状动脉综合征时早期心脏标志物的研究进展[J].诊断学理论与实践,2005,4(5):423-425. 被引量:7
  • 5[1]Uehar M, Arai Y, Watanabe's, et al. Compaarison of plasma and urinary phytoestrogens in Japanese and Finnish women by time-resolved fluoroimmunoassay[J] . Biofactors, 2000; 12(1 -4): 217 -225.
  • 6[2]Wang GJ, Lapcik O, Hampl R, et al. Time-resolved fluoroimmunoassay of plasma daidzein and genistein[J]. Steroids, 2000;65(6): 339 - 348.
  • 7[3]L'homme R, Brouwers E, Al-Maharik N, et al. Time-resolved fluoroimmunoassay of plasma and urine O-desmethylangolensin[J].Steroid Biochem Mol Biol, 2002; 81 (4 - 5): 353 - 361.
  • 8[4]Yamada H, Satoh R, Yamashita T, et al. Development of a time-resolved fluoroimmunoassay(TR-FIA) for testosterone:measurement of serun testosterone concentrations after testosterone treatment in the rainbow trout(Oncorhynchusmykiss)[J]. Gen Comp Endocrinol, 1997; 106(2): 181 - 188.
  • 9[5]Mehto P, Ankelo M, Hinkkanen A, et al.A time-resolved fluoroimmunoassay for the detection of microcystins, cyanobacterial peptede hepa to toxins[J]. Toxin, 2001; 39:831 - 836.
  • 10[6]Uehara M, Lapcik O, Hampl R, et al. Rapid analysis of phytoestrogens in human urine by time-resolved fluoroimmunoassay[J]. Steroid Biochem Mol Biol, 2000; 72(50:273 - 282.

共引文献237

同被引文献40

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部